Frequency Response - Meridian Nortel 1 Option 11C Technical Reference Manual

Nortel networks network system technical reference guide
Hide thumbs Also See for Nortel Meridian 1 Option 11C:
Table of Contents

Advertisement

Frequency Response

Table 41
Frequency Response for 2 wire and 4 wire interfaces
Frequency (Hz)
200
300
3000
3200
3400
Frequency Response, or Attenuation Distortion, at a given frequency is the
difference between the loss at the test frequency and the loss at the reference
frequency. Table 41 gives the frequency response for 2 wire and 4 wire
interfaces.
2 Wire Interface
Minimum
0
-0.5
-0.5
-0.5
0
Notes to Table 41
1
The symbol (+) denotes a loss and the symbol (-) denotes a gain.
2
Reference Sources:
µ-Law -1024 Hz -10 dBmO
A-Law - 820 Hz -10 dBmO
Transmission parameters
Maximum
5
1.0
1
1.5
3.0
Option 11C and 11C Mini
Page 165 of 544
4 Wire Interface
Minimum
Maximum
0
-0.5
-0.5
-0.5
0
Technical Reference Guide
3
0.5
0.5
1.5
3.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents