Table 37
Insertion Loss from IPE Ports to IPE Ports (measured in dB) (Part 2 of 2)
4 Wire (ESN)
E&M Trunk
5.5
CO/FX/WATS
Loop Tie
Trunk
2.5
Table 38
Insertion Loss Digital Ports To IPE Ports (measured in dB) (Part 1 of 2)
500/2500
Line
Digital Ports
Tie Trunk
8.5
Satellite Tie
Trunk
(See note 1)
2.5
3
2.5
-1
0
0
-3.5
Digital
Line
6
2.5
-3
2.5
Option 11C and 11C Mini
Transmission parameters
IPE Ports
0.5
0.5
0.5
0
IPE Ports
2/4 Wire E&M
4 Wire (ESN)
Trunk
E&M Trunk
3.5
0
-2.5
0.5
0
0.5
Page 161 of 544
0
0
0
0.5
-0.5
CO/FX/WATS
Loop Tie
Trunk
3
2.5
-3
0
-0.5
0
Technical Reference Guide
0.5
-2.5
-0.5

Hide quick links: