  • Page 1 SB-E-2-440 ISS.03 Operation Manual PRi – Trans-Tech Gravity Primer Spraygun ® P 2 - 8...
  • Page 2: Ec Declaration Of Conformity

    II 2 G X, Suitable for use in Zones 1, and 2 Important: These Sprayguns are suitable for use with both waterbased and solvent based coating materials. The design uses EPA compliant atomising (Devilbiss Trans-Tech®) technology to reduce overspray and improve coating efficiency. Nozzles and Needles are manufactured in Stainless Steel.
  • Page 3: Personal Protective Equipment

    SAFETY WARNINGS Always wear eye protection when Fire and explosion spraying or cleaning the spraygun Solvents and coating materials Gloves must worn when can be highly flammable or spraying cleaning combustible when sprayed. ALWAYS equipment refer to the coating material suppliers Training –...
  • Page 4: Parts List

    Parts List Ref. No Description Part Number Air Cap/Retaining ring PRI-407-310 Spring Clip JGA-156-K5 +**2 Nozzle PRI-2-**-K Baffle & Seal GTI-425-K Baffle Seal - Kit of 5 GTI-33-K5 Packing GTI-439-K2 Spreader Valve GTI-404-K Stud and Screw GTI-408-K5 Needle PRI-3-K Spring and Pad GTI-409-K5 Bushing GTI-402-K...
  • Page 5: Specification

    Specification Air supply connection - Universal BSP and NPS Maximum static inlet pressure - = 9 bar (130 psi) Nominal gun inlet pressure with gun triggered - 2 bar (29 psi) Gun Weight - 765g Materials of Construction Gun body Anodised Aluminium Nozzle Stainless steel...
  • Page 6: Installation

    Installation Important: To ensure that this equipment bore. The hose must be conductive reaches you in first class condition, electrical bond from protective coatings have been use. Flush spraygun to earth should be checked the equipment through with a suitable with an ohmeter.
  • Page 7: Replacement Of Parts

    distorted spray patterns Lubrication – stud/screw (6), needle (7) and air valve (11) should be oiled each Ensure the tip of the nozzle is clean day. and free from damage. Build up of dried paint can distort the spray pattern. Replacement of Parts Nozzle (2) and Needle (7) –...
  • Page 8 ® Scrubs are pre- moistened heavy duty towels, capable of removing paint, grease, grime and dirt from hands and tools without the use of water. Available in buckets of 72 wipes. Order 192218 ITW Finishing Systems and Products Ringwood Road, Bournemouth, BH11 9LH, England.