14
OPERATING THE ENGINE
(1) Parked regeneration switch
(2) DPF INHIBIT switch
BRegeneration Operating Procedure
1. Start the engine.
(Make sure that the DPF INHIBIT switch lamp
Switch lamp OFF: Auto Regeneration Mode activated.
Switch lamp ON: Regeneration Inhibit Mode activated.
A When the engine is started, the "Auto Regeneration" mode is automatically activated.
A "Regeneration Inhibit" mode is activated, when the DPF INHIBIT switch is pushed after the engine is started.
2.
When a specific amount of PM has built up in the DPF, the regeneration indicator turns "ON".
Continue to operate the tractor, and the regeneration process will begin automatically, make sure you are
working in a safe area as DPF and exhaust temperature will rise.
When the regeneration cycle has completed, the regeneration indicator turns "OFF".
IMPORTANT:
A When ambient temperature is so low or when working with such extraordinary use of electricity that the
regeneration conditions are not satisfied, the regeneration indicator starts flashing.
If the regeneration indicator turns "ON" for a while and then starts flashing, keep on working and rev
up the engine to the maximum rpm so that the regeneration indicator stops flashing and remains "ON".
Operating Procedure for Auto Regeneration Mode
(3) Engine warning indicator
(4) Regeneration indicator
(5) Parked regeneration indicator
is "OFF".)