Hotpoint PK 640 R L GH /HA EE Operating Instructions Manual page 11

Hide thumbs Also See for PK 640 R L GH /HA EE:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 8
DATA PLATE
Electrical
see data plate
connections
This appliance conforms to the following
European Economic Community directives:
- 2006/95/EEC dated 12/12/06 (Low
Voltage) and subsequent amendments
- 2004/108/EEC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments
- 93/68/EEC dated 22/07/93 and
subsequent amendments.
- 2009/142/EEC dated 30/11/09 (Gas) and
subsequent amendments.
- 2012/19/EC and subsequent
amendments.
Burner and nozzle specifications (for 65 cm versions only)
Table 1
Burner
Diameter
(mm)
Reduced Fast (RR)
100
Semi Fast (S)
75
Auxiliary (A)
55
DCDR
30
internal
Double
flame
DCDR
130
TOTAL
Supply pressures
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m³
A
RR
DC
S
PK 640 R GH/HA EE
PK 640 RL GH/HA EE
Thermal
Thermal
By-pass
power
power
1/100
kW
kW
(p.c.s.*)
(p.c.s.*)
Reduced
Nominal
(mm)
0.70
2.60
39
0.40
1.65
28
0.40
1.00
28
0.40
0.90
27
1.65
3.60
55
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
Liquid Gas
Nozzle
Flow*
1/100
(g/h)
(mm)
***
**
Nominal
80
189
186
64
120
118
50
73
71
44
65
64
60x2+44
262
257
28-30
37
20
25
35
45
Natural Gas
Thermal
Nozzle
Flow*
power
1/100
(l/h)
kW
(p.c.s.*)
(mm)
2.60
122(H3)
248
1.65
96(Z)
157
1.00
79(6)
95
0.90
74
86
343
3.60
94x2+74
20
17
25
GB
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pk 741 rqo gh /ha eePk 750 r gh /ha ee