Before reading this manual This is a basic operation manual for installation and use of an IDIS network camera. Users who are using this product for the first time, as well as users with experience using comparable products, must read this operation manual carefully before use and heed to the warnings and precautions contained herein while using the product.
Before reading this manual Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. Important Safeguards 1.
• Slow shutter support for improved low-lighting video IDIS Discovery program to change network camera capture performance settings or the IDIS Solution Suite Compact program • Day & Night feature (built-in IR cut filter changer) to manage multiple network cameras. In addition, the...
Part 1 – Introduction Accessories Upon purchasing the product, check inside the box to make sure all the following accessories are included. External appearances and colors of the accessories may vary depending on the model. Network Camera C-Mount Ring Installation Parts Protective Cover (attaches to camera) DC Adapter (12V) / Ferrite Core Operation Manual CD...
Part 1 – Introduction Overview Side Product color and design may vary depending on the model. Front Protective Cover C-Mount Ring Back Focus Adjustment Ring Mount Bracket SD Card Slot DC-B1103 / DC-B1203 only DC-B1103 / DC-B1203 Built-in Microphone 1 Protective Cover only If the lens is not attached to the camera, use the protective cover to protect the image sensor.
Part 1 – Introduction 5 SD Card Slot DC-B1103 / DC-B1203 only Pull on the connection cover and then insert a microSD card into the slot. (An SLC (Single Level Cell) or MLC (Multi Level Cell) card by SanDisk or Transcend is recommended) •...
DC-B1103 / DC-B1203 models only) on or using the IDIS Discovery program from a remote Release the button and then gently pull on the wire location. A factory reset will reboot the system. For to ensure a secure connection. To disconnect the...
Part 1 – Introduction Back I/O Connector DC-B1103 / DC-B1203 only VIDEO DC 12V FGND NETWORK GND 3 Grounding Auto Iris Lens Connector Audio Out Audio Video Out Grounding Power Audio In Network Port Grounding Network LED Alarm Out (Active Alarm Low - Open Collector Power LED...
Powered on monitor its images from a remote computer over the network. For more information on network Not connected to Network LED On connection setup, refer to the IDIS Discovery network operation manual. Power LED/ Flashing Software upgrade...
Part 1 – Introduction Installation DC Type Auto Iris Lens The lens must be purchased separately. If you'd like to purchase a lens, contact your camera retailer. This Solder on the lens connection line to the connector camera supports manual iris lenses and DC type auto socket, if necessary.
Part 1 – Introduction CS-Mount Lens Dimensions Front 75.62 mm Remove the protective cover from the camera. Turn the lens in clockwise direction and mount it on the camera. C-Mount Lens Side 129.32 mm 125.82 mm Remove the protective cover from the camera. Turn the mount ring in clockwise direction and mount the ring on to the camera.
Part 2 - Camera Connection Use the camera by connecting to DirectIP™ NVR or non DirectIP™ NVR, VMS such as IDIS Solution Suite Compact. With DirectIP™ NVR-based Layout Audio In Audio Out Power Alarm Out Sensor In Network Camera VGA/HDMI...
TYPE 1 Alarm In/Out, Audio In/Out and SD card recording are supported by models only. The contents after page 17 are only for users using the camera with non DirectIP™ NVR connection or VMS connection such as IDIS Solution Suite Compact.
- The DirectIP™ NVR also allows you to control all camera settings directly from the NVR, without the need for a computer. Launch the IDIS Discovery program and from the list, select a camera whose protocol you wish to For more information on configuring camera settings change.
Part 3 - Remote Setup Remote Setup Quick Setup Launch the IDIS Discovery program and then from DC-B1001 / DC-B1101 the main screen, select a network camera whose settings you wish to change. Click on the Setup icon. Select Remote Setup from the Setup menu to load the Remote Setup screen.
Part 3 - Remote Setup System • Miscellaneous - ONVIF Protocol: Select to enable ONVIF protocol use. However, ONVIF Protocol is available only to users belonging to the standard user groups (Administrator, Operator, and User). • Setup - Load Default Setup: Restores all settings other than Date/Time to their factory defaults.
Part 3 - Remote Setup Date/Time User/Group • Date/Time: Change the camera's date/time • User/Group: Change remote camera control settings and display formats and configure the time permission settings for users and user groups. zone and daylight saving time settings. Click Apply - Add Group: Add a new user group.
Part 3 - Remote Setup Network • User/Group settings can only be configured by users belonging to the Administrator group. • There is no default password for the Administrator group's admin user. • Standard groups (Administrator, Operator, and User) cannot be edited or deleted. Authorities assigned here apply identically to ONVIF protocol user groups.
% symbol, it might not be able to connect to the camera from the IDIS Web program. The FEN Server operated by IDIS is a service to its clients and may go offline without notice for server update purposes or due to an unexpected failure.
Record, and Search ports are enabled by default and cannot be disabled. By enabling IDIS Web and RTSP ports, you will be able to use the IDIS Web program or a media player that supports RTSP (Real-Time Streaming Protocol) service to connect to the camera.
Port Number/ (If Use HTTPS has been bandwidth limit has been set. enabled, enter https instead of http). Camera's IDIS Web port number and RTSP port number must be configured correctly in order to establish a connection this way. • Port numbers of the remote program must be updated whenever the camera's port numbers are changed.
Part 3 - Remote Setup Security IEEE 802.1X Select the IEEE 802.1X option to enable IEEE 802.1X network connection authentication. • IP Filtering: Select this option to enable IP Filtering. IP Filtering allows camera access from certain IP addresses and blocks access from others. •...
Part 3 - Remote Setup Video Image Sensor Configure Image Sensor settings. Configure Camera, Streaming, Webcasting, MAT, • Mirroring: Select Horizontal Reverse or Vertical and Privacy Masking options. Reverse to flip the image horizontally or vertically. • Pivot: Enable this option and choose the direction of the pivot.
Page 28
• B&W Mode: Display the images in greyscale for greater clarity in low-lighting conditions. DC-B1001 / DC-B1101 only - On/Off: Enable/disable B&W Mode. - Auto: Allow the system to enable/disable B&W Mode automatically.
Page 29
DC-B1001 / DC-B1101 model, B&W Mode can be configured from the Image Sensor screen. Not applicable to DC-B1001 / DC-B1101 For more information on Image Sensor settings, refer to the Image Sensor on page 27. Configure Day & Night settings.
The tertiary stream may not be available depending on higher stream settings (refer to the table below). Primary Secondary Tertiary Model Resolution Resolution Resolution DC-B1001 704x480 704x480 DC-B1103 / 1280x720 1280x720 DC-B1101 DC-B1203 1920x1080 704x480...
Part 3 - Remote Setup • Multi-View Streaming: Designate a specific area Webcasting of the screen and stream images from that area only. (not applicable to the primary stream) Click Use the webcasting service to view live images from Setup to designate a streaming area. the camera on a web site.
Part 3 - Remote Setup Privacy Masking Select the MAT option to use the MAT (Motion Select Privacy Masking to set up a privacy mask Adaptive Transmission) feature during video over a specific area. The section on which a privacy transmission and recording.
• Dwell Time: Designate the alarm out duration. When an event occurs, alarm out will be generated • Not supported from the IDIS Web program. for the specified duration. • The camera must be registered to the remote •...
Part 3 - Remote Setup • FTP Server: Click Add to register a new FTP Audio Alarm server. Click Remove to remove a registered FTP server. When an event is detected, a .jpg image DC-B1103 / DC-B1203 only of the event detected is uploaded to the Primary Server.
Part 3 - Remote Setup • Settings: Configure image and upload settings. Record - Upload Type: Choose an upload type. Select Always to upload images using the settings DC-B1103 / DC-B1203 only below, irrespective of event detection. Select Select Record to record video on the SD card. First, Event to upload images using the settings below make sure that an SD card (Class 6 or higher) has when an event is detected.
Page 37
Part 3 - Remote Setup Schedule Settings Select the Schedule tab and set up a recording Select the Settings tab and configure recording schedule. settings. • Mode: Choose a recording mode. - Always - Event: Records video in event mode. In event recording mode, video is recorded when an event is detected.
• Recordings saved on the SD card can be searched and played back from the IDIS Solution Suite Compact program or remotely from the DC-B1103 / DC-B1203 remote program. For more information, refer to each program's operation manual.
DC-B1103 / DC-B1203 which system to send the message to. • Not supported from the IDIS Web program. • The camera must be registered to the remote system in order to use the Remote Callback feature.
Part 3 - Remote Setup Audio Detection • Not supported from the IDIS Web program. • The camera must be registered to the remote system in order to use the Remote Callback DC-B1103 / DC-B1203 only feature. Select Audio Detection to configure audio detection event settings.
• Not supported from the IDIS Web program. • The camera must be registered to the remote system in order to use the Remote Callback...
Page 44
Event Action must be configured correctly in order to send out emails and messages. • Remote Callback is not supported on IDIS Web. • The camera must be registered to the remote system in order to use the Remote Callback feature.
– Tools → Internet Options → Advanced → Security → Use TLS 1.0 (select) • If connecting by entering an IP address and a port number, you can connect by entering just the IP address if IDIS Web connection port number has been set to 80 (443 when entering https).
• If running IDIS Web on Internet Explorer 7.0, the bottom section of the screen may get cut off if the address bar or the status bar is shown. In this case, change Internet Options so that the address bar or the status bar is hidden.
Page 47
Part 4 - IDIS Web Press to terminate IDIS Web. Place the mouse pointer on the logo to check IDIS Web's version. TYPE 1 Displays the current time. Click to view the video in full screen. Press the ESC key on the keyboard to return to the previous screen.
Page 48
Part 4 - IDIS Web Right-click on the screen to display the pop-up menu. • Change Camera Title: Used to change the camera's name. Renaming the camera in Web Live mode does not affect the camera's name on the remote system. If no name is entered for the camera, the name used at the remote locale is shown on the screen.
& Press to terminate IDIS Web. Place the mouse pointer on the logo to check IDIS Web's version. TYPE 1 Displays time information of the video recording from the remote locale. Click to view the video in full screen. Press the ESC key on the keyboard to return to the previous screen.
Page 50
Part 4 - IDIS Web Indicates the camera's number. Zoom in or out on the video. Adjust image brightness. Apply image filters (Sharpen, Blur, Equalizer, Interpolation, and Revert) to the images. Image calibration is applied only during the paused state.
Part 5 - Appendix Setup Menu Tree (Remote Setup) DC-B1001 / DC-B1101 DC-B1103 / DC-B1203 Remote Setup Remote Setup Quick Setup Quick Setup System System Network Network Video Video Audio System System General General Date/Time Date/Time User/Group User/Group Network Network...
ID and password as a safety precaution. camera. Unable to launch IDIS If the IDIS Web login screen is not loading, check which version of Microsoft Web. Internet Explorer you are using. IDIS Web may not launch properly on versions...
Part 5 - Appendix Specifications These product specifications may change without prior notice. Camera DC-B1001 / DC-B1101 DC-B1103 / DC-B1203 Image Sensor 1/4” CMOS 1/2.7” CMOS Lens (optional) Manual iris, DC type auto iris (megapixel Manual iris, DC type auto iris (megapixel...
Page 55
RJ-45 RJ-45 RS485 Serial Port Terminal Block Use these ports for previewing video and not monitoring video. General DC-B1001 / DC-B1101 / DC-B1103 / DC-B1203 Exterior Dimensions 75.62mm x 61.02mm x 129.32mm (W x H x D) Packaging Dimensions 194mm x 113mm x 149mm...
Admin/Watch/Recording/Search Ports Quality Bitrate Control Resolution RTSP Port Camera Name 20, 23 Compression Date/Time Time Sync DSCP Use FEN FEN Server Use HTTPS Frame Rate User/Group Use UPnP IDIS Web Port IP Filtering Network Bandwidth Limit ONVIF Protocol Ver 1.1...