Install The Venting System, Flashing And Termination - Majestic NV360 Homeowner's Installation And Operating Manual

Vermont castings decorative gas appliance
Table of Contents

Advertisement

Vermont Castings Majestic Products NV360/580 Series
INSIDE
OUTSIDE
Fig. 7 EB-1 receptacle.
6. Connect the white wire of the power line to the
chrome screw of the socket assembly.
7. Connect the ground wire of the supply line to the
green screw of the socket assembly.
8. Refit the socket assembly back into the electrical
box and replace the cover plate. Secure the cable
with the clamp on the outside of the unit to prevent
strain on the connections.
9. The EB-1 electrical junction box is now ready to
supply power to the FK12 or FK24 fan kits if fitted.
8
ELECTRICAL BOX
FP580
Install the Venting System, Flashing
and Termination
NOTE: The NV360 uses a 6" B-vent system. The
NV580 uses an 8" B-vent system (refer to Accessories,
Page 25, for adapter).
Refer to venting installation instructions provided by the
B-vent manufacturer.
Refer to Page 4, Figure 1 to locate chimney centerline
dimension from a combustible back wall.
Minimum vertical chimney height - 12 feet
(3.65m) (measured from the bottom of the fire-
place)
Maximum vertical height - 40 feet (12m)
Minimum height with two elbows - 18 feet (4.6m)
Elbow requirements allow a maximum of two 90°
elbows or four 45° elbows per installation. (Two
45° elbows = one 90° elbow.) Refer to the venting
chart for proper elbow offset runs.
For firestop positioning, refer to Figure 8. Only one (1)
firestop required per frame. NOTE: A firestop is not
required at the roof.
Attic Insulation
Firestop position when area above ceiling is an attic
Ceiling Installation
Firestop position when area above ceiling is NOT an attic
Fig. 8 Firestop/draftstop positions.
Nails (4)
Firestop Spacer
Joist
(Firestop/draftstop
appearances may
vary. Only one (1)
firestop required
per frame.)
FP384
20003565

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nv580

Table of Contents