Technical Data; Installation; Pump Location; Suction Conditions - Grundfos MTC Installation And Operating Instructions Manual

Table of Contents

Advertisement

3. Technical data

MTC
Minimum liquid
temperature [°C] / [°F]
Maximum liquid
temperature [°C] / [°F]
Maximum ambient
temperature [°C] / [°F]
Maximum operating
pressure [bar] / [psi]
Enclosure class

4. Installation

The pump must be installed so that per-
sons cannot accidentally come into con-
tact with the hot surface of the motor.

4.1 Pump location

The pump is designed for tank mounting in vertical
position. The pump is positioned in a hole cut into
the cover of the tank (upper side) and is secured to
the tank by four hexagon head screws through the
holes in the mounting flange. It is recommended to fit
a sealing gasket between the pump flange and tank.
Note: The pumps can only be mounted in vertical
position. The MTC 2 and 4 must have access to the
tank from the drain channel in the motor stool.
MTC 2 and 4
Drain
channel
Fig. 1
4
8, 12
2 and 4
and 16
–10/–14
+90/+194
+55/+131
+40/+104
8/116
12/174
IP 54 [TEFC]
c
L
Fig. 2
Pump mounting flange dimensions:
MTC
D1 [mm] / [in]
D2 [mm] / [in]
D3 [mm] / [in]
L [mm] / [in]
C
X [mm] / [in]

4.2 Suction conditions

The bottom of the pump strainer must be at least
25 mm above the bottom of the tank.
The pumps are designed to provide full performance
down to a level of A mm above the bottom of the
strainer.
At a liquid level between A and B mm above the bot-
tom of the strainer, the built-in priming screw will pro-
tect the pump against dry running.
MTC
A [mm] / [in]
B [mm] / [in]
Fig. 3
MTC 2 and 4
4 x X
D1
D2
D3
2 and 4
8, 12 and 16
140/5.51
180/7.09
160/6.30
210/8.27
180/7.09
200/8.27
121/4.76
100/3.94
¾" NPT
1 ¼" NPT
7/0.28
9/0.35
2 and 4
8, 12 and 16
37/1.1
40/1.6
22/0.9
25/1.0
A
A
B
B
25 mm
25 mm