Removal of Electronic Expansion Valve

Procedure
Step
Pull out the electronic
1
expansion valve coil.
Remove the sheets of
2
putty.
Before working, make
sure that the refrigerant
gas is empty in the circuit.
Be sure to apply nitrogen
replacement when
heating up the brazed
part.
Heat up the 2 brazed
3
parts of the electronic
expansion valve and
remove it.
213
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Electronic expansion valve coil
Electronic expansion valve
Points
(R2737)
Warning
Be careful not to get yourself
burnt with the pipes and other
parts that are heated by the
gas brazing machine.
Warning
If the refrigerant gas leaks
during work, ventilate the
room. (If the refrigerant gas is
exposed to flames, toxic gas
may be generated.)
Caution
From the viewpoint of global
environment protection, do
not discharge the refrigerant
(R2739)
gas in the atmosphere. Make
sure to collect all the
refrigerant gas.