Indoor Unit - Daikin FTXG25JV1BW Service Manual

Inverter pair wall mounted type j-series
Hide thumbs Also See for FTXG25JV1BW:
Table of Contents

Advertisement

Indoor Unit

1. Indoor Unit

Connectors and
PCB (1): Control PCB
Other Parts
1) S21
2) S25
3) S32
4) S41
5) S42
6) S46
7) S200
8) H1, H2, H3,
9) JB
10) LED A
11) F1U
12) V1
PCB (2): Signal Receiver / Display PCB
1) S51
2) S52
3) S1W
4) H1P
5) H2P
6) JA
PCB (3): INTELLIGENT EYE Sensor PCB
1) S36
11
Connector for centralized control (HA)
Connector for INTELLIGENT EYE sensor PCB
Connector for indoor heat exchanger thermistor
Connector for swing motors
Connector for reduction motor (front panel mechanism) and limit switch
Connector for signal receiver / display PCB
Connector for fan motor
Connector for terminal board
FG
Fan speed setting when compressor stops for thermostat OFF
JC
Power failure recovery function (auto-restart)
∗ Refer to page 223 for detail.
LED for service monitor (green)
Fuse (3.15 A, 250 V)
Varistor
Connector for control PCB
Connector for room temperature thermistor
Forced operation ON/OFF button
LED for operation (multi-color)
LED for INTELLIGENT EYE (green)
Address setting jumper
∗ Refer to page 222 for detail.
Connector for control PCB
Printed Circuit Board Connector Wiring Diagram
SiBE041012_A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents