Renkus-Heinz RHAON User Manual page 16

Hide thumbs Also See for RHAON:
Table of Contents

Advertisement

Users Manual
The three operational modes of RHAON, Connect, Control and Supervise all have their own unique Properties window (see below).
Notice that the vertical pane on the left side of each window is identical except for the number of output bar graphs. Single amplifier
loudspeakers, such as the CF61-2R, will have a single meter, bi-amped loudspeakers will have 2 output meters and 3-way loud-
speakers will have 3 output meters. The Connect, Control and Supervise tabs at the top of the window allow you to switch between
the three operating modes without returning to the main window.
The Connect Properties window gives you the ability to:
1. Select and connect the multiple inputs of Rhaon
empowered loudspeakers to the amplifier(s)
2. Select and send input and output signals to the
CobraNet network
3. Select one of the CobraNet digital audio channels, if
CobraNet's multi channel digital audio capability is being
used.
The Control Properties window provides setup and con-
trol facilities for the loudspeaker's onboard DSP. It
includes controls for the:
1. Compressor
2. 8-band parametric equalizer, hi & lo band roll off and
shelving filters
3. Signal delay
4. Priority override controls.
The Supervise Properties window allows you to:
1. Monitor and test the status of each transducer's driver
2. Control the volume of the monitor loudspeaker, if one
is provided
3. Check the status of the voltage detect circuit, the fault
relay and the Ethernet network.
16

Advertisement

Table of Contents
loading

Table of Contents