2.2

Removal of the Fan Motor / Propeller Fan

Procedure
before disassembling work.
Step
Remove the top panel
and the front panel.
1. Remove the electrical box
cover.
Loosen the screw on
1
the back of the shelter.
Undo the two claws and
2
remove it.
Release the four claws
3
of the
electrical box
cover
and remove it.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
Procedure
Claws
Shelter
(R2688)
Outdoor Unit
Points
This procedure is not
necessary to remove the
propeller fan only.
The claws have been
released since the front
panel was removed.
131