Daikin B-Series Service Manual page 146

Floor standing inverter pair
Hide thumbs Also See for B-Series:
Table of Contents

Advertisement

Si06-313
Step
2
Push the claw up to
release the cable way
board.
Open the cable way
board.
Disconnect the
3
harnesses from the
power supply PCB.
HL
(black) ···· to the
terminal strip
HE2
(yellow / green) ····
to the terminal strip
(earth)
HAC1
(black) ···· from
the control PCB (AC1)
HE1
(yellow / green) ····
from the control PCB
(E)
Disconnect the
4
connectors of the front
side.
S20: electronic
expansion valve
S40: overload protector
S80: four way valve
S90: thermistors
(discharge pipe,
outdoor air,
heat exchanger)
Removal Procedure
Procedure
Outdoor Unit
Points
Power supply PCB (outdoor
unit)
HE1
V3(varistor)
HAC1
HE2
HL
FU1 250V 30A
(soldered)
(R2707)
137