Refractory, Grate And Valve Assembly Removal - Heat & Glo 6000CBV-IPI Owner's Manual

Installation and operation
Table of Contents

Advertisement

C. Refractory, Grate and Valve Assembly
Removal
It may become necessary to remove the optional refrac-
tory, grate and valve assemblies. This task should be per-
formed by a qualifi ed service technician. The optional
refractory, grate and base refractory do not need to be
removed to service the burner assembly.
NOTICE: Remove optional refractory before removing
grate. If grate is removed fi rst, damage to refractory will
occur.
Note: The optional refractory must be
removed before removing the grate.
f i r e - p a r t s . c o m
Figure 3.2 Grate Removal
14
Heat & Glo • 6000CBV-IP, 8000CBV-IPI • 2167-900 Rev. C • 9/09
Note: The base refractory must be
removed to access screws.
Figure 3.3 Base Refractory Removal
Figure 3.4 Valve Assembly Removal
BASE REFRACTORY

Advertisement