Appliance Setup; Fixed Glass Assembly Removal And Replacement; Remove The Shipping Materials/Install Bottom Glass Shield - Heat & Glo MEZZO36-C Installation Manual

Hide thumbs Also See for MEZZO36-C:
Table of Contents

Advertisement

11

Appliance Setup

A. Fixed Glass Assembly Removal and Re-
placement
WARNING! Risk of Asphyxiation! Handle fixed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
• DO NOT strike, slam or scratch glass.
• DO NOT operate fireplace with glass removed, cracked,
broken or scratched.
• Replace as a complete assembly.
Removing Fixed Glass Assembly
1. Remove the decorative barrier front from fireplace and
set aside on work surface.
2. Remove bottom glass shield. See Figure 11.2.
3. Locate the glass latches that are on the upper edge of
the glass frame of the appliance. See Figure 11.1.
4. Use both index fingers to release the glass clips.
5. Allow glass to tilt forward. Grasp glass on the upper
return lip of glass frame and lift up and out. The glass
should lift easily out of the bottom retaining lip.
Replacing Fixed Glass Assembly
1. Locate retaining lip on lower front face of firebox.
2. Place glass assembly into retaining lip end. Tilt top of
glass assembly toward fireplace.
3. Assure proper left to right placement of glass and
engage all four spring latches.
4. Replace bottom glass shield and decorative barrier
front.
GLASS CLIPS
BOTTOM RETAINING LIP
Figure 11.1 Fixed Glass Assembly
Heat & Glo • MEZZO36-C/ST-C, MEZZO48-C/ST-C, MEZZO60-C/ST-C, MEZZO72-C/ST-C Installation Manual • 2600-980 Rev. D • 9/19
B. Remove the Shipping Materials/Install
Bottom Glass Shield
Remove shipping materials from inside or underneath
the firebox. Verify all components are with the fireplace.
Unwrap the bottom glass shield and replace in the same
location as shown in Figure 11.2.
Figure 11.2 Bottom Glass Shield Location
CAUTION! Risk of Overheating! DO NOT remove com-
ponent insulation from top of component heat shield.
Electrical components will be damaged.
COMPONENT INSULATION
Figure 11.3 Component Insulation Location
69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents