Replacing Gauge Set For Needle Width - SunStar KM-857 Series User Manual

Table of Contents

Advertisement

19) Replacing gauge set for needle width

(1) Disassembling order
[Caution] Turn off the power switch.
1. Open the hook cover.
2. Remove the needle
3. Disassemble the needle holder
(※ Turn it towards the arrowed direction for removal: KM-867 series)
4. Lift the presser bar lifter to raise the presser foot
5. Disassemble the presser foot
6. Disassemble the needle plate
7. Disassemble the feed dog
(2) Assembling order
※After assembling in the reverse order of disassembling, adjust the left and right hook base.
34
[Adjusting the left/right hook base]
For KM-867 series
When replacing with a wider or narrower gauge
than the needle width in use, the hook edge
and needle distance need to be readjusted. To
do so, loosen the screws ①②③④, make the
adjustment, and then fasten them back.