2.
Attach a grounding cable to the chassis lug by inserting a 6-gauge cable (item 1 in Figure 18). Using a
hand-crimping tool (Tyco Electronics 58433-3 or equivalent), crimp the lug (item 2 in Figure 18) so
that the cable is held securely.
Figure 18. Grounding the Chassis
3.
Connect the opposite end of the grounding cable to the nearest grounding post at your site.

Installing a Fan Module

The C9010 switch requires three fan modules for normal operation. Three field-replaceable fan modules
are shipped with the base configuration. To ensure proper temperature and airflow control, the three fan
modules must always be installed and operating properly.
NOTE: If a fan fails, replace the fan module within two minutes to avoid a shutdown of installed line
cards.
Installing the Hardware
27