Avaya G250 and G250-BRI Branch Office Media Gateways w/FIPS Non-Proprietary Security Policy
Version 1.2

3.2. G250-BRI Ports and Interfaces

The G250_BRI cryptographic module provides the physical ports and logical
interfaces defined in Table 4 below.
#
Interface
Qty
1. ETH LAN
8
POE
2. ETH WAN
1
3. CCA
1
Analog Line
2
4.
Analog Trunk
1
5.
© 2005 Avaya Inc. May be reproduced only in its original entirety [without revision].
Figure 4 – G250-BRI faceplate
Logical interface definition
Data input, data output, status
output, control input, power
output
Data input, data output, status
output, control input
Power output.
Analog Phones (Line1/Line2)
Data input/output, power output
Analog Phone Trunks.
Data input/output, power input
Wednesday, 14 December, 2005
Comments
Supports local area network connectivity.
Supports wide area network connectivity.
Contact Closure Adjunct. Powers two contact-
closure relays.
Line 2 ceases to be a data input/output from the
module and is directly connected to Analog
Trunk, providing a power interface, when an
emergency state occurs:
a)
Power failure
b)
Failure to communicate with a call
controller
c)
Firmware error state
The Trunk ceases to be a data input/output from
the module and is directly connected to Analog
Line 2, providing a power interface, when an
emergency state occurs:
a)
Power failure
b)
Failure to communicate with a call
controller
c)
Firmware error state