Troubleshooting

4. Troubleshooting

4.1

Error Codes and Description

System
Indoor
Unit
Outdoor
Unit
68
Error Codes
00
Normal
U0
Refrigerant shortage
U2
Low-voltage detection or over-voltage detection
U4
Signal transmission error (between indoor unit and outdoor unit)
UA
Unspecified voltage (between indoor unit and outdoor unit)
A1
Indoor unit PCB abnormality
A5
Freeze-up protection control or heating peak-cut control
A6
Fan motor (DC motor) or related abnormality
C4
Indoor heat exchanger thermistor or related abnormality
C7
Front panel open / close fault
C9
Room temperature thermistor or related abnormality
E1
Outdoor unit PCB abnormality
E5
OL activation (compressor overload)
E6
Compressor lock
E7
DC fan lock
E8
Input overcurrent detection
EA
Four way valve abnormality
F3
Discharge pipe temperature control
F6
High pressure control in cooling
H0
Compressor system sensor abnormality
H6
Position sensor abnormality
DC voltage / current sensor abnormality (25/35 class only)
H8
CT or related abnormality (RXG50K2V1B only)
H9
Outdoor temperature thermistor or related abnormality
J3
Discharge pipe thermistor or related abnormality
J6
Outdoor heat exchanger thermistor or related abnormality
L3
Electrical box temperature rise
L4
Radiation fin temperature rise
L5
Output overcurrent detection
P4
Radiation fin thermistor or related abnormality
Signal transmission error on outdoor unit PCB
U7
(RXG50K2V1B only)
: Displayed only when system-down occurs.
Description
SiBE041012_B
Reference
Page
75
78
80
83
69
70
71
73
74
73
84
86
88
89
90
91
93
94
95
97
100
101
103
103
103
105
106
108
103
82
Service Diagnosis

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents