Capacitor Voltage Check - Daikin FTXG-J Service Manual

Wall mounted type j-series
Hide thumbs Also See for FTXG-J:
Table of Contents

Advertisement

SiBE041012_B
RXG50K3V1B

5.13 Capacitor Voltage Check

Check No.21
RXG50K2V1B only
Before this check, be sure to check the main circuit for short circuit.
With the circuit breaker still on, measure the voltage according to the drawing of the model in
question. Be careful never to touch any live parts.
Service Diagnosis
4
3
2
Tester
Multimeter
(DC voltage range)
1
(R18183)
Check
(R14700)
119