3 WIRING

3.1 Terminal connection diagram

Source logic
Main circuit terminal
Control circuit terminal
*1. DC reactor (FR-HEL)
When connecting a DC reactor, remove the
jumper across P1-P/+.
3-phase
AC power
supply
Control input signals (No voltage input allowed)
Terminal functions vary
with the input terminal
assignment.
(Pr. 178 to Pr. 184)
Multi-speed selection
*2
When using terminals
PC-SD as a 24VDC
power supply, take care
not to short across
terminals PC-SD.
Contact input common (Sink*)
24VDC power supply/ max. 100mA load current
Contact input common(Source*)
*(Common for external power supply transistor)
Frequency setting signal (Analog)
*3. Terminal input specifica-
tions can be changed
by analog input specifi-
cations
*4 The input area can be set
via Parameter (Pr. 267).
Set the voltage/current
input switch in the "V"
position to select voltage
input (0 to 5V/0 to 10V)
and "I" (initial value) to
select current input
(0/4 to 20mA.)
*5 It is recommended to use a 1 kΩ, 2 W
potentiometer when the frequency
setting signal is changed frequently.
CAUTION
To prevent a malfunction due to noise, keep the signal cables more than 10cm away from the power cables.
After wiring, wire offcuts must not be left in the inverter. Wire offcuts can cause an alarm, failure or malfunction. Always keep the
inverter clean. When drilling mounting holes in a control box etc., take care not to allow chips and other foreign matter to enter the
inverter.
Set the voltage/current input switch in the correct position. An incorrect setting may cause a fault, failure or malfunction.
4
Earth
Earth
Forward
rotation start
Reverse
rotation start
High
speed
Medium
speed
Low
speed
Output
stop
RESET
Frequency
setting
potentiometer
Ω
1 k
,1/2 W
*5
Terminal 4
input
(Current
input)
*4 Voltage/current
Connector for plug-in
option connection
Brake unit
Jumper

Main circuit

Control circuit
0–5VDC
0–10VDC
PU
Analog common
connector
4 to 20mADC
USB
0 to 5VDC
0 to 10VDC
connector
input switch
Option connector
(Option)
*6 Brake resistor (FR-ABR, MRS, MYS)
Install a thermal relay to prevent an overheat
and burnout of the brake resistor.
Earth
Standard control terminal block
Relay output
Terminal functions vary
Relay output
by Pr. 192 "ABC terminal
(Alarm output)
function selection"
Open collector output
Terminal functions vary with the
output terminal assignment.
Running
(Pr. 190 to Pr. 191)
Frequency detection
Open collector output common
Sink/source common
Analog signal output
(0 to 10VDC)
M
Motor
3~