6 PARAMETER

For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check can be made
from the operation panel. For details of parameters, refer to the instruction manual.
Remarks
The parameters marked
The parameters marked with
(initial value) is set in Pr. 77 Parameter write selection.
Parameters
Name
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
Multi-speed setting
4
(high speed)
Multi-speed setting
5
(middle speed)
Multi-speed setting
6
(low speed)
7
Acceleration time
8
Deceleration time
Electronic thermal
9
O/L relay
DC injection brake
10
operation frequency
DC injection brake
11
operation time
DC injection brake
12
operation voltage
13
Starting frequency
Load pattern
14
selection
15
Jog frequency
Jog acceleration/
16
deceleration time
17
MRS input selection
High speed
18
maximum frequency
Base frequency
19
voltage
*1
Differ according to capacities.
6%: FR-E740-026 or less
4%: FR-E740-040 to 095
3%: FR-E740-120 and 170
2%: FR-E740-230 and 300
*2
Differ according to capacities.
5s: FR-E740-095 or less
10s: FR-E740-120 and 170
15s: FR-E740-230 and 300
*3
Differ according to capacities.
4%: FR-E740-016 to 170
2%: FR-E740-230 and 300
12
are the simple mode parameters.
in the table allow its setting to be changed during operation even if "0"
Setting Range
Initial Value
0 to 30%
6/4/2 *
0 to 120Hz
120Hz
0 to 120Hz
0Hz
0 to 400Hz
50Hz
0 to 400Hz
50Hz
0 to 400Hz
30Hz
0 to 400Hz
10Hz
5s/10s/
0 to 3600/360s
15s *
5s/10s/
0 to 3600/360s
15s *
Rated
inverter
0 to 500A
output
current
0 to 120Hz
3Hz
0 to 10s
0.5s
0 to 30%
4%/2% *
0 to 60Hz
0.5Hz
0 to 3
0
0 to 400Hz
5Hz
0 to 3600/360s
0.5s
0, 2, 4
0
120 to 400Hz
120Hz
0 to 1000V,
8888
8888, 9999
Parameters
Name
1
Acceleration/
20
deceleration
reference frequency
Acceleration/
21
deceleration time
increments
Stall prevention
22
operation level
Stall prevention
operation level
23
compensation factor
at double speed
Multi-speed setting 4
24 to 27
2
speed to 7 speed
Acceleration/
2
29
deceleration pattern
selection
Regenerative
30
function selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
3
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
RUN key rotation
40
direction selection
Up-to-frequency
41
sensitivity
Output frequency
42
detection
Setting Range
Initial Value
1 to 400Hz
50Hz
0, 1
0
0 to 200%
150%
0 to 200%, 9999
9999
0 to 400Hz,
9999
9999
0, 1, 2
0
0, 1, 2
0
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0 to 400Hz,
9999
9999
0, 0.01 to 9998
0
0, 1
0
0 to 100%
10%
0 to 400Hz
6Hz