Mounting; Processor Unit - Furuno FCV-1900/B/G Installation Manual

Table of Contents

Advertisement

1.

MOUNTING

1.1

Processor Unit

1.1.1
Installation considerations
The processor unit can be installed on a desktop or a bulkhead. When selecting a
mounting location, keep in mind the following points:
• Locate the unit out of direct sunlight.
• Select an installation location that is well ventilated.
• Locate the unit where shock and vibration are minimal.
• Leave sufficient space around the unit for maintenance and servicing.
• Face the cable connectors downward for bulkhead mounting.
• Keep the compass safe distances shown on page i.
1.1.2
Tabletop mounting
1) Drill four pilot holes in the tabletop for the self-tapping screws.
2) Screw four self-tapping screws (5x20, supplied) into the pilot holes, leave 5 mm
protruding.
3) Set the processor unit to the screws, then slide the processor unit to the front to fix
the unit.
4) Fasten the screws to fix the unit in place.
1.1.3
Bulkhead mounting
1) Drill fore pilot holes in the bulk-
head for the self-tapping screws.
2) Screw four self-tapping screws
(5x20, supplied) to the pilot
holes, leave 5 mm protruding.
3) Hang the processor unit on the
screws. The cable connectors
should be faced downward.
4) Fasten the screws to fix the unit
in place.
1
Face the cables
downward