Holiday Mode; Dry Concrete Function - Panasonic WH-ADC0916G9E8 WH-UX09FE8 Service Manual

Hide thumbs Also See for WH-ADC0916G9E8 WH-UX09FE8:
Table of Contents

Advertisement

* During External Switch OFF condition, it is allow to change the setting and also timer operation.

12.20 Holiday Mode

Purpose:
Promotes energy saving by allowing the user to stop the system during holiday and enables the system to
resume at the preset temperature after holiday.
Control details:
Range of days can be set in holiday mode is from 1 to 999 days.
o
After days of holiday have been set, heat pump will stop and only resume operation at 12.00am at the
o
end of holiday countdown.
Start condition:
Unit is OFF and holiday mode is set.
o
* The day the holiday mode was set is counted as day 1.
Stop condition:
OFF/ON button is pressed.
o
Holiday counter is reached.
o

12.21 Dry Concrete Function

Purpose
Provide heat to floor heating panel and dry the wet concrete during installation.
Setting condition:
Dry concrete parameter can be set through control panel by selecting dry concrete menu.
o
Parameters are possible to set up to 99 days with different target set temperature.
o
Control details:
Dry concrete operation can be activate under Service Mode 3.
o
Once dry concrete function start, day 1 setting temperature will be send to indoor unit by control panel.
o
Unit will operate heat mode with dry concrete preset water outlet temperature. (No shift value added to
o
the preset water outlet temperature)
After complete day 1 setup operation, day 2 data will be send to indoor at 12.00am on the second day.
o
Each preset data will be send everyday until dry concrete mode is complete, unit will turns OFF and exit
o
dry concrete function.
3 ways valve and booster heater will turn OFF and 2 ways valve will turns ON.
o
Cancel condition:
Unit will turns OFF and exit dry concrete function.
o
OFF signal is received by pressing OFF/ON button or error H76 is occurred.
o
HEATER
OPERATION
ON
REMOTE
CONTROLLER
OFF
LED
ON
REMOTE
CONTROLLER
SIGNAL
ON
EXTERNAL
CONTROLLER
SWITCH
ON
UNIT
OFF
AUTO
HEAT
MON TUE WED THU FRI SAT SUN
COOL
ON
TANK
OFF
FORCE
During EXTERNAL SW OFF,
display "EXT SW OFF"
ON
OFF
OFF
86
ACTUAL
HEATER
hr
BOOSTER
°C
QUIET
SETTING
kwh
hr
STATUS
°C
SERVICE
OFF

Hide quick links: