Maintenance And Service - Bosch AL 1115 CV Original Instructions Manual

Hide thumbs Also See for AL 1115 CV:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8
OBJ_BUCH-1256-004.book Page 10 Monday, December 16, 2013 4:51 PM
10 | English
Continuous Lighting of the Battery Charge Indicator 2
Continuous lighting of the battery charge indicator 2 indicates that
the battery is fully charged or that the temperature of the battery is
not within the allowable charging temperature range, and cannot be
charged for this reason. The battery is charged as soon as the allow-
able charging temperature range is reached.
When the battery is not inserted, continuous lighting of the battery charge indicator 2 indi-
cates that the mains plug is inserted in the socket and that the battery charger is ready for
operation.
Troubleshooting – Causes and Corrective Measures
Cause
Continuous lighting of the battery charge indicator 2
No charging procedure possible
Battery not (properly) inserted
Battery contacts contaminated
Battery pack defective
Battery charge indicator 2 does not light up
Mains plug of battery charger not plugged in
(properly)
Socket outlet, mains cable or battery charger
defective
Working Advice
With continuous or several repetitive charging cycles without interruption, the charger can
warm up. This is not meaningful and does not indicate a technical defect of the battery charg-
er.
A significantly reduced working period after charging indicates that the battery is used and
must be replaced.

Maintenance and Service

Disposal
Battery chargers, accessories and packaging should be sorted for environmental-friendly re-
cycling.
Do not dispose of battery chargers into household waste!
Only for EC countries:
According to the European Guideline 2012/19/EU for Waste Electrical
and Electronic Equipment and its implementation into national right, bat-
tery chargers that are no longer usable must be collected separately and
disposed of in an environmental correct manner.
Subject to change without notice.
1 609 92A 0F5 | (16.12.13)
Corrective Measure
Properly insert battery into battery charger
Clean the battery contacts (e.g. by inserting
and removing the battery several times) or
replace the battery
Replace the battery
Insert mains plug (fully) into the socket outlet
Check the mains voltage; have the battery
charger checked by an authorised after-sales
service agent for Bosch power tools