Daikin FDM10CXV1 Technical Manual page 105

Table of Contents

Advertisement

Model: FDYM38CXV1 - RY35DXV1
Heating Mode
ID DB
-9°C
TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW)
15°C
4.741
4.741
17°C
4.618
4.618
19°C
4.496
4.496
21°C
4.373
4.373
23°C
4.368
4.368
25°C
4.363
4.363
27°C
4.358
4.358
Remark:
AFR: Air fl ow rate (CFM)
EWB: Entering Wet Bulb Temp. (°C)
EDB: Entering Dry Bulb Temp. (°C)
TC: Total Cooling / Heating Capacity (kW)
SC: Sensible Cooling / Heating Capacity (kW)
PI: Power Input (kW)
Notes:
1. Ratings shown are net capacities.
2.
shows nominal capacities.
3. Direct interpolation is permissible. Do not extrapolate.
4. Unit is able to operate at ambient from 19°C to 46°C DB (cooling) / -9°C to 18°C WB (heating) without pressure trip.
-6°C
-5°C
5.949
5.949
6.352
6.352
5.827
5.827
6.230
6.230
5.706
5.706
6.109
6.109
5.584
5.584
5.987
5.987
5.491
5.491
5.866
5.866
5.399
5.399
5.744
5.744
5.306
5.306
5.623
5.623
Frost Region
Outdoor WB
6°C
12°C
10.782 10.782 13.198 13.198 14.406 14.406 15.614 15.614
10.537 10.537 12.838 12.838 14.004 14.004 15.170 15.170
10.293 10.293 12.478 12.478 13.602 13.602 14.726 14.726
10.049 10.049 12.118 12.118 13.200 13.200 14.282 14.282
9.740
9.740
11.758 11.758 12.798 12.798 13.838 13.838
9.431
9.431
11.398 11.398 12.396 12.396 13.394 13.394
9.122
9.122
11.038 11.038 11.994 11.994 12.949 12.949
Performance Data
15°C
18°C
102

Hide quick links:

Advertisement

Table of Contents
loading