Synchronizing with echo sounder or other sonar
To synchronize the transmission of the FSV-24 with an echo sounder or other
type of sonar, make connections as shown below.
For current driven KP
Processor
For voltage driven KP (12 V)
Processor
Voltage driven KP output
Processor
Menu setting
See EXT KP INPUT on page 3-8.
EXT-KP
unit
EXT-KP-IN-H
EXT-KP-IN-C
EXT-KP
unit
EXT-12VKP-H
0V
EXT-KP
unit
INTKP1
GND
INTKP2
GND
INTKP3
GND
KP signal
8
E/S
9
Sonar
KP signal
10
E/S
7
Sonar
KP signal
1
E/S,
2
Sonar,
3
Current
4
indicator
5
6
2-13