2.3.3
How to connect cables to the monitor unit
Connect the monitor cable and control cable to the monitor (FURUNO-supplied
monitor) unit as below.
1. Unfasten four screws (M4x10) at the rear of the monitor to loosen the cable
cover.
2. Lift and pull the cable cover to remove it.
3. Unfasten two screws (M4x10) to remove the clamp cover.
4. Lay the monitor and control cables on the clamp, and then reattach the
clamp plate to fix cables.
5. Connect eight connectors referring to the instruction sticker by the connector
board.
6. Reattach the cable cover.
Connector board
Cable cover
CN-A306 CN-A305 CN-A304
2
1
3
B
G
R
CN-A308 CN-A307
5
4
CN-A302
H
V
CN-A301 CN-A303
Clamp
Monitor unit, rear view
Monitor cable
Control cable