Fan Motor (Dc Motor) Or Related Abnormality - Daikin FTXG25CVMAW Service Manual

Hide thumbs Also See for FTXG25CVMAW:
Table of Contents

Advertisement

Si04-402A
4.4

Fan Motor (DC Motor) or Related Abnormality

A6
Remote
Controller
Display
Method of
The rotation speed detected by the
Malfunction
abnormal fan motor operation.
Detection
Malfunction
When the detected rotation speed is less than 50% of the HH tap under maximum fan motor
rotation demand.
Decision
Conditions
Supposed
Causes
Service Diagnosis
Operation halt due to short circuit inside the fan motor winding.
Operation halt due to breaking of wire inside the fan motor.
Operation halt due to breaking of the fan motor lead wires.
Detection error due to faulty indoor unit PCB.
Hall IC
during fan motor operation is used to determine