Other Functions - Daikin FTXG25CVMAW Service Manual

Hide thumbs Also See for FTXG25CVMAW:
Table of Contents

Advertisement

Main Functions
1.10

Other Functions

1.10.1
Hot Start Function
Heat Pump Only
In order to prevent the cold air blast that normally comes when heating is started, the
temperature of the heat exchanger of the indoor unit is detected, and either the air flow is
stopped or is made very weak thereby carrying out comfortable heating of the room.
*The cold air blast is also prevented using a similar control when the defrosting operation is
started or when the thermostat gets turned ON.
1.10.2
Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.10.3
ON/OFF Button on Indoor Unit
An ON/OFF switch is provided on the front panel of the unit. Use this switch when the remote
controller is missing or if its battery has run out.
Every press of the switch changes from Operation to Stop or from Stop to Operation
1.10.4
Titanium Apatite Photocatalytic Air-Purifying Filter
This filter combines the Air Purifying Filter and Titanium Apatite Photocatalytic Deodorizing
Filter in a single highly effective unit. The filter traps microscopic particles, decompose odours
and even deactivates bacteria and viruses. It lasts for three years without replacement if
washed about once every six months.
1.10.5
Mold Proof Air Filter
The air filter net is impregnated with a safe, odourless mould preventative to make the filter
virtually immune to mould.
1.10.6
Self-Diagnosis Digital Display
The microcomputer continuously monitors main operating conditions of the indoor unit, outdoor
unit and the entire system. When an abnormality occur, the LCD remote controller displays error
code. These indications allow prompt maintenance operations.
1.10.7
Auto-restart Function
Even if a power failure (including one for just a moment) occurs during the operation, the
operation restarts in the condition before power failure automatically when power is restored.
(Note) It takes 3 minutes to restart the operation because the 3-minutes standby function is
activated.
26
Push this button once to start operation. Push once again to stop it.
This button is useful when the remote controller is missing.
The operation mode refers to the following table.
Mode
Cooling Only
COOL
Heat Pump
AUTO
In the case of multi system operation, there are times when the unit does not activate with
this button.
ON / OFF button
(R3304)
Temperature setting
22ºC
25ºC
Si04-402A
Air flow rate
AUTO
AUTO
Function and Control