Page 1
technical data RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air...
Page 2
Daikin Europe N.V. is participating Daikin Europe N.V. is approved by LRQA for its Quality in the EUROVENT Certification Programme. Management System in accordance with the ISO9001 Products are as listed in the EUROVENT standard.
Outdoor units for pair application + Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. + They are fitted with a swing compressor, renowned for its low noise and high energy efficiency.
• Pair Application, Inverter Controlled Unit • R-410A • RXG25,35CVMB Specifications ELECTRICAL DATA RXG+FTXG25C Representative unit combination Power supply Comp. Indoor unit Outdoor unit Hz-volts Voltage range Max. 50Hz-253V FTXG25CVMBW RXG25CVMB 50-230 0.22 0.50 Min. 50Hz-207V Max. 50Hz-253V FTXG25CVMBS RXG25CVMB 50-230 0.22 0.50 Min. 50Hz-207V 3D045220...
• Pair Application, Inverter Controlled Unit • R-410A • RXG25,35CVMB Dimensional drawings unit (mm) RXG25,35C Wall height on air outlet side = less Minimum space for air passage than 1200 Drain outlet 4 x holes for anchor bolts (M8 or M10) (I.D.
• Pair Application, Inverter Controlled Unit • R-410A • RXG25,35CVMB Operation range RXG25,35C Cooling Heating Indoor temp. (°CWB) Indoor temp. (°CDB) Notes: The graphs are based on the following conditions: + Equivalent piping length 7.5 m + Level difference + Air flow rate high 3D045140 •...
• Pair Application, Inverter Controlled Unit • R-410A • RXG25,35CVMB Piping diagrams RXG25,35C Outdoor unit Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Filter Muffler with Muffler with filter filter Propeller fan Four way valve on: cooling Field piping Liquid stop valve Muffler...
• Pair Application, Inverter Controlled Unit • R-410A • RXG25,35CVMB Wiring diagrams RXG25,35C Field wiring Indoor Outdoor Note 1. Refer to the name plate for the power requirements. In case of cooling In case of heat pump : Protective earth only type type (outdoor)
• Pair Application, Inverter Controlled Unit • R-410A • RXG25,35CVMB Installation RXG25,35C Outdoor unit installation drawings Wrap the installation pipe with the finishing tape from bottom to top Model 25 / 35 class Max. allowable length 20 m Max. allowable height Additional refrigerant required for refrigerant pipe exceeding 20 g/m...