Control Panel Removal; Control Adjustments - Millivolt Models - Raypak 206A Installation & Operating Instructions Manual

Gas-fired pool & spa heater
Table of Contents

Advertisement

CONTROL PANEL REMOVAL

1. Remove screw from front door. Set aside door for
serviceability.
2. Remove (4) screws from sides of control panel.
3. Rotate control panel down until panel stops. Do
not force.
NOTE: Caution must be used to not damage controls
or wiring.
CONTROL ADJUSTMENTS -
DIGITAL AND ADVANCED FLAME TECHNOLOGY
(AFT) MODELS
Temp Adjust Buttons
LCD Display
KNURLED
SCREW
Mode Button
ON
OFF
32

CONTROL ADJUSTMENTS - MILLIVOLT MODELS

The water temperature is controlled by the heater ther-
mostat on the upper front panel of the heater. The
control center contains an On/Off switch and one ther-
mostat.
The thermostat is fitted with a means of limiting the
upper temperature limit below the maximum level.
The knob stop adjustment ring illustrated below is
adjustable by loosening the set screw, rotating the
knob stop ring to the desired location and re-tightening
the set screw.
SPA TEMPERATURE
RANGE
SET SCREW
KNOB STOP RING
KNOB STOP SHOWN ABOVE IS
IN THE SPA TEMPERATURE RANGE
POOL TEMPERATURE
RANGE
STAND-BY
TEMPERATURE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

336a266a267a337a407a406a ... Show all