WS5000 Series: WS5100 Installation Guide
WARNING!
1.3 Warnings
Read all installation instructions and site survey reports, and verify correct equipment installation before connecting
•
the system to its power source.
Remove jewelry and watches before installing this equipment.
•
Install the equipment in a rack with adequate dimensions and weight allowances.
•
Verify that the rack is anchored and cannot tip over or break away from its mountings.
•
Verify that the unit is grounded before connecting it to the power source.
•
Verify that any device connected to this unit is properly wired and grounded.
•
Connect all power cords to a properly wired and grounded electrical circuit.
•
Verify that the electrical circuits have appropriate overload protection.
•
Attach only approved power cords to the device.
•
Symbol Technologies strongly recommends the use of an Uninterruptible Power Supply (UPS) that supports the
•
WS5100 power rating. Not using a UPS can result in data loss or equipment damage due to a power surge or power
failure.
Verify that the power connector and socket are accessible at all times during the operation of the equipment.
•
Do not work with power circuits in dimly lit spaces.
•
Do not install this equipment or work with its power circuits during thunderstorms or other weather conditions that
•
could cause a power surge.
Verify that there is adequate ventilation around the device, and that ambient temperatures meet equipment
•
operation specifications.
1.4 Site Preparation
Consult your site survey and network analysis reports to determine specific equipment placement, port capacity,
•
power drops, and so on.
Assign installation responsibility to the appropriate personnel.
•
Identify where all installed components are located.
•
Verify appropriate rack mounting requirements.
•
Provide a sufficient number of power drops for your equipment.
•
Ensure adequate, dust-free ventilation to all installed equipment.
•
Identify and prepare Ethernet and console port connections.
•
Verify that cable lengths are within the maximum allowable distances for optimal signal transmission.
•
Verify that the WS5100 is powered through an Uninterruptible Power Supply (UPS).
•