WS5000 Series: WS5100 Installation Guide
Using the supplied console cable, connect the WS5100 serial port to an
4.
RS-232 (DB-9) serial port on a separate computer (the "configuration computer").
On the configuration computer, configure a terminal emulation application (such as
5.
HyperTerminal) as follows:
Terminal Type
Port
Terminal Settings
The WS5100 does not need to be fully deployed into the wired or wireless network to
complete the installation steps outlined in "
page 10.
3.3 Supplying Power to the WS5100
Verify that the WS5100 power switch is off before connecting the AC power cord.
1.
Plug an approved AC power cord into the power connector at the back of the WS5100.
2.
Plug the cord into a standard AC outlet with a voltage range of 100 to 240 VAC.
3.
Toggle the power switch (at the back of the WS5100) to the On position.
4.
.
WARNING!

3.4 Verifying the Installation

View the LEDs on the front panel of the WS5100 to ensure the device is functioning
properly. The normal LED pattern follows this path:
VT-100
COM 1-4 (depending on which COM port you're using.)
19200 bps transfer rate
8 data bits
no parity
1 stop bit
no flow control
no hardware compression
Preliminary Configuration through the CLI
An improper shutdown can render the WS5100 inoperable
such that it may require service by Symbol Support. Please
do not remove AC power or turn off the WS5100 (by
toggling the on/off switch on the back of the device) without
first following the shutdown procedure described in "
" on page 24. An abrupt loss of power can
Down the WS5100
corrupt the information stored on the device.