Technical Data

Jigsaw
Article number
Laser module
Stroke rate control
Stroke rate preselection
Orbital action
Rated power input
Output power
Stroke rate at no load n
0
Stroke
Cutting capacity, max.
– in wood
– in aluminium
– in non-alloy steel
Bevel cuts (left/right), max.
Weight according to EPTA-Procedure 01/2003
Protection class
The values given are valid for nominal voltages [U] of 230/240 V. For lower voltage and models for specific countries, these
values can vary.
Please observe the article number on the type plate of your machine. The trade names of the individual machines may vary.
Laser module (PST 800 PEL/PST 900 PEL)
Laser type
Laser class
Operating and storage
temperature
Batteries
Noise/Vibration Information
Measured values determined according to EN 60745.
Typically the A-weighted noise level of the machine is:
sound pressure level 85 dB(A); sound power level
96 dB(A). Uncertainty K=3 dB.
Wear hearing protection!
The typical hand/arm vibration is below 2.5 m/s
The vibration emission level given in
WARNING
this information sheet has been meas-
ured in accordance with a standardised test given in
EN 60745 and may be used to compare one tool with
another.
The vibration emission level will vary because of the
ways in which a power tool can be used and may
increase above the level given in this information sheet.
This could lead to a significant underestimate of expo-
sure when the tool is used regularly in such a way.
18 | English
3 603 C51 1.. 3 603 C52 1.. 3 603 C53 1..
W
W
spm
mm
mm
mm
mm
°
kg
Note: To be accurate, an estimation of the level of
exposure to vibration experienced during a given period
nm
650
of work should also take into account the times when
the tool is switched off and when it is running but not
mW
<1
actually doing the job. This may significantly reduce the
2M
exposure level over the total working period.
°C
0 ... +40

Declaration of Conformity

3 x 1.5 V
(LR44)
PST 700 PE: We declare under our sole responsibility
that this product is in conformity with the following
standards or standardization documents: EN 60745
according to the provisions of the directives
89/336/EEC, 98/37/EC.
PST 800 PEL/PST 900 PEL: We declare under our
sole responsibility that this product is in conformity with
the following standards or standardization documents:
EN 60745, EN 60825-1 according to the provisions of
2
the directives 89/336/EEC, 98/37/EC.
.
Dr. Egbert Schneider
Senior Vice President
Engineering
14.08.2006, Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
PST 700 PE
PST 800 PEL PST 900 PEL
600
620
330
340
500–3100
500–3100
23
23
70
80
12
15
5
6
45
45
2.1
2.1
/ II
/ II
Dr. Eckerhard Strötgen
Head of Product
Certification
650
360
500–3100
23
90
20
10
45
2.2
/ II
2 609 932 567 • 14.8.06