KOBE RAX9430SQB-1 Installation Instructions And Operation Manual

KOBE RAX9430SQB-1 Installation Instructions And Operation Manual

Brillia series

Advertisement

Quick Links

Brillia Series
Model No.
RAX9430SQB-1 (30")
RAX9430SQB-DC30-1 (30")
RAX9430SQB-DC46-1 (30")
KOBE Range Hoods
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
RAX9436SQB-1 (36")
RAX9436SQB-DC30-1 (36")
RAX9436SQB-DC46-1 (36")

Advertisement

Table of Contents
loading

Summary of Contents for KOBE RAX9430SQB-1

  • Page 1 KOBE Range Hoods Brillia Series Model No. RAX9430SQB-1 (30”) RAX9436SQB-1 (36”) RAX9430SQB-DC30-1 (30”) RAX9436SQB-DC30-1 (36”) RAX9430SQB-DC46-1 (30”) RAX9436SQB-DC46-1 (36”) INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...
  • Page 2 3. Contact your merchant for product replacement due to shipping damages, cosmetic damages or defects. 4. For all other issues, call 1-877-BUY-KOBE (289-5623), or e-mail to info@koberangehoods.com NO RETURN, NO REFUND, NO EXCHANGE IF: 1. PRODUCT HAS BEEN INSTALLED 2.
  • Page 3: Table Of Contents

    [ENGLISH] - READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS ..................1 COMPONENTS OF PACKAGE....................3 INSTALLATION .......................... 4 OPERATING INSTRUCTIONS....................7 MAINTENANCE ......................... 8 SPECIFICATIONS ........................9 MEASUREMENTS & DIAGRAMS .....................10 PARTS LIST ..........................12 CIRCUIT DIAGRAM ........................14 TROUBLE SHOOTING ......................15 WARRANTY ..........................16 WARRANTY INFORMATION FORM ..................18...
  • Page 4: Important Safety Instructions

    Any repair carried out without the supervision of KOBE authorized agents will automatically void the warranty. KOBE will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.
  • Page 5 What to Do In The Event Of a Range Top Grease Fire • SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
  • Page 6: Components Of Package

    Model No.: RA0930DC Extension Duct Cover RA0946DC (Included in RAX94 SQB-DC46-1 ONLY) {L} Duct Cover Extension Model No.: RA0946DC *Pre-installed Knob attached to baffle filter *Pre-installed FOR MORE INFORMATION, PLEASE VISIT OUR W EBSITE www.koberangehoods.com CONTACT KOBE RANGE HOODS AT (626) 775-8880.
  • Page 7: Installation

    INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to TABLE 1. (All calculation in inches.) TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36") C = Preferred Height of Counter Top to Hood Bottom (Minimum 26"...
  • Page 8 Preparation before Installation Figure 1 NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. A straight, short venting run will allow the hood to perform more efficiently.
  • Page 9 Figure 4 Wiring to Power Supply THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL LOCK SERVICE PANEL...
  • Page 10: Operating Instructions

    OPERATING INSTRUCTIONS Note: For best results, turn fan on prior to any preparation or cooking and keep fans running while cooking. Adjust speed as needed. To operate the fan function • Press button to choose from speed. o Q = QuietMode™ speed o L = Low speed o H = High speed •...
  • Page 11: Maintenance

    MAINTENANCE For optimal performance, clean the range hood surface and baffles regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve its fine appearance. 1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth. 2.
  • Page 12: Specifications

    CONTROLS Mechanical Push Button LIGHTS 3-watt LED light x 2 HOOD DIMENSION RAX9430SQB-1 / RAX9430SQB-DC30-1 / RAX9430SQB-DC46-1 (W x D x H) 29-3/4” x 20-1/2” x 12-3/16” RAX9436SQB-1 / RAX9436SQB-DC30-1 / RAX9436SQB-DC46-1 35-1/4” x 20-1/2” x 12-3/16” DUCT COVER DIMENSION RA092DC-1 10-5/8”...
  • Page 13: Measurements & Diagrams

    ***All inch measurements are converted from millimeters. Inch measurements are estimated. ***All measurements in ( ) are millimeters. MODEL NO.: RAX9430SQB-1 (30”) RAX9436SQB-1 (36”)
  • Page 14 MODEL NO.: RAX9430SQB-DC30-1 / RAX9436SQB-DC30-1 Extension Duct Cover RA0930DC * For the diagram of hood dimension, please refer to Page 11. MODEL NO.: RAX9430SQB-DC46-1 / RAX9436SQB-DC46-1 Extension Duct Cover RA0946DC * For the diagram of hood dimension, please refer to Page 11.
  • Page 15: Parts List

    PARTS LIST MODEL NO.: RAX9430SQB-1 (30”) RAX9436SQB-1 (36”) RAX9430SQB-DC30-1 (30”) RAX9436SQB-DC30-1 (36”) RAX9430SQB-DC46-1 (30”) RAX9436SQB-DC46-1 (36”) DESCRIPTION MODEL /SIZE PART NO. Duct Cover-Mounting Bracket L1-0203-0092 Duct Cover RA092DC-1 12-09200-61 6” Round Plastic Exhaust L1-0505-0003 LED Light (3W) L1-0403-0301 Control Switch...
  • Page 16 MODEL NO.: RAX9430SQB-1 (30”) RAX9436SQB-1 (36”) RAX9430SQB-DC30-1 (30”) RAX9436SQB-DC30-1 (36”) RAX9430SQB-DC46-1 (30”) RAX9436SQB-DC46-1 (36”)
  • Page 17: Circuit Diagram

    CIRCUIT DIAGRAM MODEL NO.: RAX9430SQB-1 (30”) RAX9436SQB-1 (36”) RAX9430SQB-DC30-1 (30”) RAX9436SQB-DC30-1 (36”) RAX9430SQB-DC46-1 (30”) RAX9436SQB-DC46-1 (36”)
  • Page 18: Trouble Shooting

    TROUBLE SHOOTING Issue Possible Cause Solution After The power is not on. Make sure the circuit breaker and the unit’s Installation, power is ON. Use a voltage meter to check both motors the power supply. and lights are The wire connection is not secure. Check and tighten wire connection.
  • Page 19: Warranty

    TWO-YEAR LIMITED WARRANTY FOR PARTS AND LABOR ON KOBE PREMIUM/ BRILLIA SERIES: For two years from the date of your original invoice from a KOBE authorized dealer, we will, at our sole discretion, choose to repair or replace the product free of charge that failed due to manufacturing defects.
  • Page 20 3. Have the model number 4. Have the serial number 5. Have a description of the nature of any defect in the product or part TO REQUEST WARRANTY SERVICE, PLEASE CONTACT THE KOBE RANGE HOODS SERVICE CENTER: KOBE SERVICE CENTER...
  • Page 21: Warranty Information Form

    1. Date of purchase 2. Model No. 3. Serial No. For warranty service or spare parts purchase contact: KOBE Service Center Toll Free: 1-855-800-KOBE (5623) Email: kobe@adcoservice.com For service in Canada and to report a problem, please contact: Tel: 1-626-775-8880 Email: customer.service@koberangehoods.com...
  • Page 22 Arcadia, CA 91006 USA www.koberangehoods.com This KOBE hood is made for use in the USA and CANADA only. We do not recommend using this hood overseas as the power supply may not be compatible and may violate the electrical code of that country. Using a KOBE hood overseas is at your own risk and will void your warranty.

Table of Contents