LAMP SPECIFICATIONS:
Voltage
220-240V
Frequency
50Hz
1371 lm
Nominal lumens
Wattage
23W
Nominal life time of the lamp
10,000 hrs
Number of switching cycles
before premature lamp
30,000
failure
Colour temperature
6400K
Warm-up time up to 60 % of
40s
the full light output
Dimmable
No
Lamp dimensions (mm)
140 x 59
Lamp mercury content to an
2.5
accuracy of 0.1mg
Cap type
ES (E27)
Rated Wattage
22.5W
Rated luminous flux
1371 lm
Rated lamp lifetime
10,000
Colour rendering index Ra
80%
Lamp power factor
0.55
Lumen maintenance factor at
50%
end of nominal life
Starting time
0.9s
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
"WEEE Directive" effective August 2005—UK
WEEE Regulations effective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST - DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
Issue 2013
FOR PRODUCT ADVICE:
• T: 01933 673 144
• F: 01933 678 083
• E: sales@eterna-lighting.co.uk
FL124BPIR
MODELNO.
A
XXX
22.50
874/2012
CLEANING:
To avoid dust build-up and ensure proper
functioning of the floodlight, please wipe the sensor
lens lightly with a damp cloth every 3 months.
Disconnect the power and clean the exterior only of
this fitting with a moist (not wet) cloth.
Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specific
instructions regarding individual installations.
For breakage information visit:
www.eterna-lighting.co.uk
Visit our website:
www.eterna-lighting.co.uk
CFL23W
MODELNO.
A
++
A
kWh/1000h
Pack contents:
1 x Fitting
1 x 23W ES CFL lamp
23W Low Energy Floodlight With 180° PIR
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
INSTALLATION INSTRUCTIONS
A guide for qualified electricians
Model:
FL124BPIR
These instructions are provided as a guideline to assist you.
AND RETAIN FOR FUTURE REFERENCE

Advertisement

loading
Need help?

Need help?

Do you have a question about the FL124BPIR and is the answer not in the manual?

Questions and answers

Summary of Contents for Eterna FL124BPIR

  • Page 1 DISPOSE WITH HOUSEHOLD WASTE. 1 x 23W ES CFL lamp it to the place where you bought it. Our Technical Team will gladly advise on any Eterna Lighting Model: product, but may not be able to give specific instructions regarding individual installations.
  • Page 2 You are advised at every stage of your installation to Appr. Fig 3 it. Eterna Lighting cannot accept any liability for 2.5M double-check any electrical connections you have loss, damage or premature failure resulting from made.
  • Page 3 Power Cable Wall INSTALLATION: INSTALLATION: UNDERSTANDING THE CONTROLS: Termin Mounting When installing the PIR flood light refer to Fig.4 (Referring to Fig.5 opposite) Support opposite. ADJUSTING THE DURATION TIME: Fig 4 Screws 01) Switch off the mains before commencing The length of time that remains switched on after installation.
  • Page 4 TROUBLESHOOTING AND USER HINTS: NOTE: all passive infra red detectors are more sensitive in cold and dry weather than warm and wet weather. PROBLEM POSSIBLE CAUSE SUGGESTED REMEDY 1. No mains voltage Check all connections, and MCB fuses / switches 2.