General rules

Range of application
Use machines for cleaning tasks with high-pressure water jet and detergents or with
high-pressure water jet without detergents only.
Inspections
The machine must be inspected according to the "Guidelines for Liquid Spray Devices"
at least once every 12 months by a qualified person, to ensure that continued safe
operation is guaranteed. The results of the inspection are to be recorded in writing. This
may be done in any form. For inspection reports see pages 38-39.
High-pressure cleaners used for commercial purposes have
to be checked by a qualified person at least every 12 months!
Accident prevention
The machine is designed for accidents to be impossible if used correctly. The operator is
to be notified of the risk of injury from hot machine parts and the high pressure water jet.
The "Guidelines for Liquid Spray Devices" must be complied with. (see pages 8 and 9).
Oil change:
The first oil change should be carried out after approximately 50 operating hours. After
that no further oil change will be necessary for the life cycle of the high-pressure
cleaner. If it becomes necessary during repairs, or because the oil has a greyish colour
to perform an oil change, then the oil draining screw should be opened and the oil emp-
tied into a container. The oil is to be caught in the reservoir and disposed of in an appro-
ved manner. New oil: 0.25 l - Motor oil: W 15/40.
Oil leakage: If oil leaks contact your nearest after-sales
service (dealer) at once. (Ecological damage, damage to
the transmission)
In case of increased humidity or fluctuations in
temperature development of condensed water is possi-
ble; if the oil turns grey, you must change it.