Kranzle 1132 Operating Manual page 21

Hide thumbs Also See for 1132:
Table of Contents

Advertisement

21
Pressure gauge shows little pressure, the water from the nozzle comes
in squirts: Most likely the valves are soiled or sticky.
The pressure gauge shows little pressure
despite fully turned up pressure regulation.
The water from the lance comes in squirts.
The HP hose vibrates.
(Inside the pressure gauge is no water but
a filling with glycol to damp the vibration of
the pointer.)
Proceeding:
Unscrew all 6 valves, one after the other
(hexagonal brass screws, 3 in a row,
vertically and horizontally)
Take out valve body (with green or red
plastic coating) and O-ring by means of
needle nose
pliers. Check O-ring for damage. In
case of a damage the O-ring has to be
replaced.
Take a wire (paper clip) and clean valves
under running water.
Do not forget the O-ring during
reassembly!