Water Inlet Without Heat Exchanger - Bosch GV 630 S Repair Instructions

Table of Contents

Advertisement

4.21

Water inlet without heat exchanger

When the filler valve has been opened, the water flows through the
flow sensor towards the integrated inlet via a free flow channel and
into the regeneration chamber. When the regeneration chamber has
been filled, the water flows through the water softening system via the
overflow channel and then flows as soft water into the pump sump.
When the electronics module has detected the prefill level via the flow
sensor, the circulation pump switches on and is filled up to the wash
level.
The water volume of completed rinse cycles is recorded by the
electronics counter which determines when the water softener
requires regeneration. Before each regeneration step the electronics
check whether the capacity of the water softener is adequate for
a complete "Normal Programme Sequence". If not, regeneration
starts. The water softening system is regenerated and rinsed through
during the wash cycle. The
regeneration valve
system is opened for this purpose. The stored volume of water flows
into the salt dispenser via the valve, absorbs salt and flows as saline
solution through the water softening system into the pump sump.
Rinsing takes place in three stages, each with one calculated volume
of water.
A
Free flow line
B
Leakage water
C
Regeneration chamber
D
Safety pressure switch
E
To the pump sump
F
Float in the base pan
G
Salt dispenser
202_58300000104305_ara_en_b – 02.11.a
on the water softening
H
Ion exchanger
I
Regeneration valve
J
Flow sensor
K
From drainage pump
L
To the drainage hose
M
Drainage hose ventilation valve