Samsung NE597N0PBSR Servise Manual page 51

Hide thumbs Also See for NE597N0PBSR:
Table of Contents

Advertisement

4. Troubleshooting
4-1-3
Connect the sensor.
Replace the wire.
Connect the wire
properly.
After Power -> On, does
the symptom continue?
Replace the Assy Touch PCB.
Top Sensor Open Error (
Is the sensor connected?
connected properly
by burner position?
Is the sensor's real resistance is
S/W Error
The sensor has defect.
Replace the sensor.
Perform the operation again and check
if it is working properly.
: check if the sensor wire is damaged,
if the sensor housing is inserted into
the connector of the PCB.
Is the sensor wire
opened circuit?
51
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftq307nwgxNe595n0pbsr

Table of Contents