3. Disassembly and Reassembly
3-5 Replacement of the Assy-Working Coil(Continued)
Parts
Assy-Working
Coil
Explanation Photo
pull & rotate
pull & rotate
Warning
Wire connecting position is very improtant.
Please keep attention.
17
Explanation
2. Disconnect all lead wires from the
Assy-Working Coil.
3. For the replacement of Sensor-Top,
pull the Sensor-Top toward bottom
side.
4. Rotate the Sensor-Wire by
90degree until the Sensor-Top can
be remove from the Coil-Working.
5. After replacement, connect
the Sensor-Top and all lead
wires.