Storing Wood
Steps to ensure properly seasoned wood:
Stack wood to allow air to circulate freely around and
through woodpile.
Elevate wood pile off ground to allow air circulation
underneath.
Smaller pieces of wood dry faster. Any piece over 6 in.
(152 mm) in diameter should be split.
Wood (whole or split) should be stacked so both ends of
each piece are exposed to air. More drying occurs through
the cut ends than the sides.
Store wood under cover to prevent water absorption
from rain or snow. Avoid covering the sides and ends
completely.
N. Operating the Blower Control Box with
Snap Disc
1. The blower will turn on/off automatically when set to
AUTO. Figure 15.1.
2. When set to MANUAL, the fan will turn on/off only when
you turn it on or off. This setting over-rides the internal
snap disc.
3. Adjust the speed of the fan by turning the HIGH/LOW
knob to the desired setting.
O. Blower Operating Instructions
1. Initial (cold) startup: Open both controls fully by rais-
ing the Burn Rate Air Control all the way up until it stops
and push the Start-up Air Control back until it stops. The
blower tends to cool the appliance. Leave the blower off
until the burn is well established, i.e., 30 minutes.
2. High Burn Setting: Both controls are open. Burn Rate
Air Control is pulled up and the Start-up Air Control is fully
pushed in. Blower may remain on.
3. Medium High Burn Setting*: Burn Rate Air Control
is closed then opened to 1 inch (pull up )to fully open.
Blower may remain on.
4. Medium Low Burn Setting*: Burn Rate Air Control is
closed then opened to 1/4 inch to 1/2 inch. Leave the
blower off until the burn is well established, i.e., 30 min-
utes.
5. Low Burn Setting*: Burn Rate Air Control is closed.
Leave the blower off until the burn is well established, i.e.,
30 minutes.
*NOTE: For burn settings 3 to 5 the Start-up Air Control
needs to be pushed in (Open) then pulled forward to acti-
vate the Automatic Combustion Control (ACC).
July 8, 2015
MANUAL: over-
rides the internal
snap disc
Figure 15.1
NOTE: For maximum efficiency and lowest emissions,
when operating the blower in either the automatic or
manual setting for the low and medium low burn settings
leave the blower off until the burn is well established, i.e.,
30 minutes.
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostat on, then adjusting back towards "OFF" as far as
possible without turning the blower off. For a low blower
speed, turn the control knob clockwise as far as possible
NOTICE!
Do NOT operate a circulating fan within close proxim-
ity, approximately 4 ft (1.2m), of appliance
• Can reverse air flow, blowing hot air into appliance
cavity.
• Can damage appliance blower due to overheating.
7075-208D
VOYAGEUR GRAND
Blower Controls Under Ash Lip
AUTO: Fan with turn ON/OFF
automatically and is controlled
by the internal Snap Disc
15