Boiler Room And Ambient Conditions; Fuel Conditions; Power Supply Conditions; Hydraulic Conditions And Water Quality - Buderus Logano GB125/22 BE Installation And Service Instructions Manual

Low emissions and high efficiency condensing oil boiler
Table of Contents

Advertisement

2
Product description
2.7.2

Boiler room and ambient conditions

Operating conditions
Temperature in the boiler room
relative humidity
Dust/airborne particles
Halogenated-hydrocarbon com-
pounds
Small animals
Fire safety
Flooding
Tab. 5 Boiler room and ambient conditions
2.7.3

Fuel conditions

Country
Fuels
Remarks
Tab. 6 Country-specific fuels and remarks
2.7.4

Power supply conditions

Operating conditions
Mains supply voltage
Circuit breaker
Frequency
Enclosure rating
Tab. 7 Power supply
2.7.5

Hydraulic conditions and water quality

Operating conditions
Operating pressure (above
atmospheric)
Permissible testing pressure
Safety temperature limitation by
TR temperature control
Safety temperature limitation by
manual reset high limit (STB)
Water quality
Tab. 8 System configuration and water quality
12
Logano GB125 BE US/CA - Technical specifications are subject to change without prior notice.
Notes – Requirement in greater detail
+40 to +104 °F
max. 90 %
No condensation or precipitation inside the boiler room
Excessive dust inside the boiler room must be avoided when the boiler is opera-
ting, e.g.:
– dust from building work
Combustion air supplied from outside must not be excessively loaded with dust
or airborne seed; if necessary, air filters should be fitted to prevent this:
– Air supply contaminated with dust from dirt roads and paths.
– Air supply contaminated with dust from production and processing facilities, e.g. quar-
ries, mines, etc.
– Airborne particles from thistles and similar
The combustion air must be free from halogen-hydrocarbon compounds.
– Identify the source of halogen-hydrocarbon compounds and seal it off. Where this is
impossible, route combustion air from areas that are not contaminated by halogenated-
hydrocarbon compounds.
Prevent small animals from entering the boiler room, particularly through the air inlet vents –
by fitting them with screens.
Maintain clearances between the boiler and flammable materials in accordance with local
regulations. A minimum clearance of 16" is required. Never store flammable materials or liq-
uids in the vicinity of the boiler.
In case of an acute risk of flooding, disconnect the boiler in time from the from its fuel and
power supply before water enters the room. Any general and burner components or control
equipment, which come into contact with water, must be replaced before re-commission-
ing.
Approved for B5 Fuel Oil (5% biodiesel (B100) according ASTM D6751)
The burner may only be operated with the specified fuel.
Clean and service once a year. Check that the entire system functions properly at the same time. Immediately rec-
tify any faults identified.
Notes – Requirement in greater detail
110 - 120 V
The outer casing/boiler must be grounded for safety reasons and in order to function correctly.
10 A
60 Hz
IP 40 (protected against contact by entry of foreign objects > 0.04 inches Ø (> 1 mm Ø ),
no water proofing)
Notes – Requirement in greater detail
15 – 44 psi
Maximum 30 psi with the supplied safety valve.
45 – 58 psi
122 – 194 °F
212 °F
The heating system may only be filled and topped up with water of domestic water quality.
We recommend a pH level of 8.2 – 9.5.
All countries
#2 Fuel oil ASTM D396-05 Type 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Logano gb125/35 beLogano gb125/30 be