Fitting The Temperature Sensor Assembly - Buderus Logano GB125/22 BE Installation And Service Instructions Manual

Low emissions and high efficiency condensing oil boiler
Table of Contents

Advertisement

5
Boiler installation
V Remove the top cover of the controls.
– Unscrew the cover screws [1].
V Secure the programming unit with self-tapping screws
[2].
5.8.2

Fitting the temperature sensor assembly

Caution: Capillary tubes can get damaged
from severe kinking or sharp burrs.
V Route capillary tubes carefully, avoiding
bending them excessively.
V Feed the capillary tubes and the sensor lead [2]
through the cable entry in the front boiler top panel [1]
to the sensor well [3].
V Roll up surplus capillary tubes and sensor lead and lay
flat on the thermal insulation.
V Feed the burner cable [4] through the cable entry in the
front boiler top panel [1] to the programming unit.
V Connect the burner cable [4] to the programming unit
as indicated by the terminal markings.
30
Logano GB125 BE US/CA - Technical specifications are subject to change without prior notice.
1
Fig. 25 Cover, removing
1
Cover screws
2
Self-tapping screws
Fig. 26 Routing and connecting cables
1
Cable entry in the front boiler cover
2
Capillary tube and sensor cable
3
Boiler sensor well
4
Burner cable
2
7 747 019 141-22.1RS