Input Power - Lincoln Electric Mobiflex 200-M Operator's Manual

Hide thumbs Also See for Mobiflex 200-M:
Table of Contents

Advertisement

E-3
WORK LAMP
CONTROL PANEL - MOBIFLEX BASE UNIT
STARTER/OL
CONTACTOR
BK
BN
BL
A1
GN
1L1
3L2
5L3
13
1
3
5
2
4
6
14
2T1
4T2
6T3
N.A.
A2
BN
GN
GND
GND
N.E.
START
N.E.
CAPACITOR
GND
MOTOR
N.F.
CONTACTOR
14
N.A.
BN
3 L 2
TRANSFORMER
BK
S T A R T
STARTER/OL
S T O P
10
N.B.
BL
B K
BL
B K
BN
WORK LAMP
BK
5
4 T 2
BN
AUTO START/STOP
N.A.
1/L1
ARC SENSOR
13 FT. CONNECTION CABLE
LAMP
N.F.
BN
6/T3
1
GN
WH
4/T2
2/T1
WH
BN
BL
A1
BK
GN
5/L3
3
A2
CONTROL PANEL - MOBIFLEX BASE UNIT
6 T 3
GN
3/L2
BN
2 T 1
WH
13
WH
6
BN
4
GN
BN
BN
GN
GND
5 L 3
GND
BL
2
1 L 1
WH
GND - Green/Yellow
BK
GN
BN
BL
GN
WH
BN
GN
BN
BN
BN
GN
N.B.
BN
N.B.
WIRE COLOR CONVENTIONS
N.C.
- Brown
FUSE
- Blue
TERMINAL
- Black
BLOCK
- Green
N.D.
- White
WH
WH
BN
MOTOR
L
GND
N.E.
N.E.
NOTES:
BL
TERMINAL BLOCK.
N.E.
CONNECTIONS TO INPUT PLUG AND FAN MOTOR ARE INTERNAL TO THE
MOBIFLEX BASE UNIT. STANDARD 115V PLUG AND 15 FT. (5M) INPUT CORD
PROVIDED.
N.A.
INSTALLATION SECTION.
THE CENTERING LINES ALMOST COVER THE MOUNTING POINTS OF THE
MOUNT WITH SELF-TAPPING SCREWS ON MARKED MOUNTING HOLES PER
PLACE STICKER ON MOUNTING SURFACE BEHIND TERMINAL BLOCK SO THAT
BN
N.D.
N.E.
TOP OPENING.
N.E.
WITH SMALL SCREWDRIVER, AND INSERT WIRE IN CORRESPONDING
GND
TO INSERT CONDUCTORS IN TERMINAL BLOCK, PUSH IN ON FRONT OPENING
N
N.C.
115V/1PH/60HZ

INPUT POWER

GND
CAPACITOR
MOUNT ON DIN RAIL.
START
N.B.
N.F. LAMP WIRES ARE WHITE WITH BLACK SLEEVES.
DIAGRAMS
N.F.
LAMP
N.F.
BK
BK
GN
BN
GN
GN
BN
WH
BL
BN
BK
1/L1
3/L2
5/L3
10
START
STOP
2/T1
4/T2
6/T3
N.A.
BK
BN
BL
BN
L
BL
N
N.E.
GND
GND
N.E.
NOTES:
N.A. MOUNT ON DIN RAIL.
N.B. MOUNT WITH SELF-TAPPING SCREWS ON MARKED MOUNTING HOLES PER
INSTALLATION SECTION.
N.C. TO INSERT CONDUCTORS IN TERMINAL BLOCK, PUSH IN ON FRONT OPENING
WITH SMALL SCREWDRIVER, AND INSERT WIRE IN CORRESPONDING
TOP OPENING.
N.D. PLACE STICKER ON MOUNTING SURFACE BEHIND TERMINAL BLOCK SO THAT
THE CENTERING LINES ALMOST COVER THE MOUNTING POINTS OF THE
TERMINAL BLOCK.
N.E. CONNECTIONS TO INPUT PLUG AND FAN MOTOR ARE INTERNAL TO THE
MOBIFLEX BASE UNIT. STANDARD 115V PLUG AND 15 FT. (5M) INPUT CORD
PROVIDED.
N.F. LAMP WIRES ARE WHITE WITH BLACK SLEEVES.
MObIFLEX 200-M
AUTO START/STOP
ARC SENSOR
WH
13 FT. CONNECTION CABLE
BN
WH
TRANSFORMER
WH
BN
BL
BN
N.B.
INPUT POWER
115V/1PH/60HZ
WIRE COLOR CONVENTIONS
BN - Brown
BL - Blue
BK - Black
GN - Green
WH - White
GND - Green/Yellow
BN
WH
TERMINAL
BLOCK
FUSE
WH
BN
WH
BN
N.B.
BN
BN
BN
S23315-2
E-3
GN
GN
N.B.
N.C.
N.D.
GN

Hide quick links: