Lincoln Electric Mobiflex 200-M Operator's Manual page 12

Hide thumbs Also See for Mobiflex 200-M:
Table of Contents

Advertisement

A-5
INSTALLING THE LAMP OPTIONS
AND ARC SENSOR
The K1669-1 Lamp Kit Includes:
Work Lamp
13 ft., 3-Wire, 20 Ga. Connection Cable
Transformer Relay Kit
The K1669-3 Lamp Kit with Arc Sensor Includes:
Work Lamp
13 ft., 3-Wire, 20 Ga. Connection Cable
Transformer Relay Kit
Factory-installed Automatic Start/Stop Arc Sensor
The K1706-1 Work Lamp Includes:
Work Lamp
13 ft., 3-Wire, 20 Ga. Connection Cable
The K1706-2 Work Lamp with Arc Sensor Includes:
Work Lamp
13 ft., 3-Wire, 20 Ga. Connection Cable
Factory-installed Automatic Start/Stop Arc Sensor
GENERAL PREPARATION
1. Pop out the sealing plate (Fig. 7, Item A) on the top
of the hood with a screwdriver.
2. Remove the six screws (Fig. 7, Item C) and the air-
flow focus vanes (Fig. 7, Item B).
3. Open the airflow throttle valve (Fig. 7, Item D).
1
3
90°
D
MOUNTING THE ARC SENSOR IN THE LAMP
HOUSING
If not installing the K1670-1 Auto start/stop arc
sensor, skip to the next step, "Mounting the lamp
housing in the hood". The K1669-3 Lamp Kit and
K1706-2 Work Lamp have the Arc Sensor built into
the lamp housing.
Client: Lincoln / Euromate
Client no/project no: 123380/170922
INSTALLATION
A
B
2
6x
2
Fig. 7
C
A
B
MObIFLEX 200-M
Note: If the lamp housing assembly has (5) leads, the
Arc Sensor is already installed. Skip to the next step
"Mounting the lamp housing in the hood."
Use a small phillips-head screwdriver to remove the
six screws that hold the lamp housing (Fig. 8, Item A)
together. Insert the sensor housing (Fig 8, Item B)
with the sensor 'eye' away from the lamp. Route all 5
leads through the lamp housing "leg" and out the
opening as shown in Figure 8. Replace the other half
of the lamp housing, and tighten the screws.
Fig. 8
MOUNTING THE LAMP HOUSING IN THE HOOD
Feed the lamp (and sensor leads, if used) through the
hole (Fig. 9, Item A) in the top of the hood; push the
top leg of the lamp housing into position, then snap in
the bottom leg. Remount the airflow focus vanes in
the open end of the hood, using the six screws (Fig. 7,
Item C).
Fig. 9
A-5
A
B
A
B
C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents