VH30AK Video
Monitor Station (shown)
APPLICATION
The VH30AK series video-intercom system allows any
number of VH30AK series inside monitor+handset sta-
tions to communicate with one or more door entry stations
with (or without) a built-in B&W camera. When used as
an apartment video-intercom system, the VH30AK can
view the caller, speak with the caller, and activate an
electric door release (if required).
PROCEDURE
1. Read installation instructions for each unit to deter-
mine equipment location and installation method.
2. Install housings and wiring.
3. Install equipment.
4. Check wiring and connect. Observe all local
and national electrical codes.
5. Apply power and check system operation.
Copyright© 2002-2006, Alpha Communications®, All Rights Reserved.
VH30AK Series (B&W Apartment Type)
Video-Intercom Installation and Use
Instructions, used with the VCU6
System Power Supply Unit(s)
HOUSING INSTALLATION AND
EQUIPMENT LOCATION
INSIDE MONITOR+HANDSET STATION(s)
Locate stations where needed at convenient speaking and
viewing height, about 4.5 feet (137 cm) from the finished
floor. Unit can be secured directly to the finished wall
surface or can be mounted over a single gang electrical
'gem' box or single gang electrical plaster ring.
DOOR ENTRY STATION(s)
Locate door entry station(s) at a convenient speaking
location at the building entry location(s). NOTE: For best
picture (video) quality DO NOT POINT CAMERA
INTODIRECTSUNLIGHT!!!
SYSTEM TRANSFORMER(s)
The SS146 (and T1240) system transformers may be
plugged into an accessible source of 117 VAC, preferably
within 50' (15 meters) of the VCU6 system power supply
unit(s), but no closer than 3 feet (1 meter).
ELECTRIC DOOR OPENER (OPTIONAL)
The DO-001 (or equivalent 12-16VAC type) electric door
release is installed in the door jamb in place of the regular
door strike plate. It can be electrically operated by the
VH30AK video monitor+handset station(s).
WIRING
INSIDE HANDSET STATIONS
Run 2 conductor #18AWG (common), 4 conductor
#22AWG (common), RG59/U (common) and 1 conduc-
tor #22AWG (selective) cable from video monitor+handset
to video monitor+handset to the central equipment location
(where the VCU6 unit is found). Additional cables may be
used to serve other monitors on other risers (lines). Cables
may be straight or twisted pair type and may be solid or
stranded conductors. Depending upon additional system
options and/or functions you may need to run additional
wires. Please consult the factory for more information.
RG59/U coax cable must be good quality, ALL COPPER,
with minimum 95% copper braiding. As with all systems,
we recommend running some spare wires, for future use.
Route cable away from AC power wiring, transformers,
fluorescent lights, light dimmers or other electrical de-
vices. Protect cable from damage. Shielded cable should
AWD075
Rev. 5 (07/06)

Advertisement

loading

Summary of Contents for Alpha Communications VH30AK

  • Page 1 VH30AK video monitor+handset station(s). APPLICATION WIRING INSIDE HANDSET STATIONS The VH30AK series video-intercom system allows any Run 2 conductor #18AWG (common), 4 conductor number of VH30AK series inside monitor+handset sta- #22AWG (common), RG59/U (common) and 1 conduc- tions to communicate with one or more door entry stations tor #22AWG (selective) cable from video monitor+handset with (or without) a built-in B&W camera.
  • Page 2 OPERATING INSTRUCTIONS be used if AC interference is a concern, or if cables cannot be run adequately spaced away from any source of electrical TO PLACE A CALL TO THE REMOTE interference. MONITOR+HANDSET UNITS: At the remote door entrance station, depress button (for a DOOR RELEASE few seconds) for apartment you wish to call.
  • Page 3 VDU-4 video distributor (if used). Check coax connector at camera(s) to make sure it is not shorted or open. Temporarily switch monitor PC board VH30AK MONITOR COMPONENT LISTING (VH250P) with one from a functioning location. 4. NO VOICE ON SYSTEM: Check volume control potentiometer on VCU6 amplifier (in both directions;...
  • Page 4 General Monitor Mounting and Wiring Information Note: There are Black and Red pigtail wires coming from terminals 'O' and 'LL' on the VH250P P.C. Board. The Black 'O' wire must jump to terminal 'O' on the monitor handset and the Red 'LL' wire must jump to terminal 'S' on the monitor handset or the monitor will not activate when the handset is signalled from the entrance station(s).
  • Page 5 TYPICAL WIRING DIAGRAM FOR SINGLE ENTRANCE SYSTEM WITH S.T.R.™ STYLE CAMERA AND ONE (1) VIDEO RISER (NO VIDEO DISTRIBUTORS) VH30AKor Note: When using the model VCU6-2 power supply instead of the VCU6 power supply, the 'KAM' terminals will be shown as 'CAM' instead.
  • Page 6 TYPICAL WIRING DIAGRAM FOR SINGLE ENTRANCE SYSTEM WITH S.T.R.™ STYLE CAMERA AND MULTIPLE VIDEO RISERS USING A SINGLE VDU-4 VIDEO DISTRIBUTOR UNIT VH30AKor Note: When using the model VCU6-2 power supply instead of the VCU6 power supply, the 'KAM' terminals will be shown as 'CAM' instead.
  • Page 7 TYPICAL WIRING DIAGRAM FOR DUAL ENTRANCE SYSTEM WITH S.T.R.™ STYLE CAMERA AND ONE (1) VIDEO RISER (NO VIDEO DISTRIBUTORS) VH30AK or Note: For systems with more than two (2) entrances, or other configurations, please consult the factory or your nearest Alpha Communications®...
  • Page 8 USE ONLY THE SUPPLIED POWER SUPPLY! POWER SUPPLY IS FOR INDOOR USE ONLY. DO NOT REMOVE THE SERIAL NO. STICKER, AS THIS WILL VOID THE WARRANTY. ALPHA COMMUNICATIONS® • 42 Central Drive • Farmingdale NY 11735-1202 TOLL-FREE TECHNICAL LINE 1-800-666-4800 • Phone: 631-777-5500 • Fax: 631-777-5599...