Alpha Communications STR QwikBus TT33-2 Installation, Programming, And User's Manual

2 wire color video intercom system

Advertisement

Quick Links

STR QwikBus™
2 wire Color Video

Intercom System

(with TT33-2, VSP333-3 and KBS3-2)
Installation, Programming, and
User's Manual
©
Copyright
2013, Alpha Communications®, All Rights Reserved
AWD184
Rev. 1.0 - 09/2013

Advertisement

Table of Contents
loading

Summary of Contents for Alpha Communications STR QwikBus TT33-2

  • Page 1: Intercom System

    STR QwikBus™ 2 wire Color Video Intercom System (with TT33-2, VSP333-3 and KBS3-2) Installation, Programming, and User’s Manual © Copyright 2013, Alpha Communications®, All Rights Reserved AWD184 Rev. 1.0 - 09/2013...
  • Page 2: Table Of Contents

    STR QwikBus™ 2 wire Color Video Intercom System Introduction Compatible Inside Stations Planning the Installation Wiring Diagrams Single Entry STR Modular Panel Multiple Entry STR Modular Panels Single Entry Custom Panel Multiple Entry Custom Panels Important Notes on Monitor Riser Connections EVB33 Distribution Units Dipswitch Settings System Camera Options –...
  • Page 3: Introduction

    The STR QwikBus™ takes advantage of the latest in digital technology to provide a high tech, high quality color video intercom system operating on a 2 common wire BUS. QwikBus™ video monitor stations all feature a crystal clear 4" LCD Color screen (measured diagonally) and can be surface or flush mounted (with optional UMV1000 flush housing).
  • Page 4: Planning The Installation

    How many apartments? QwikBus™ can run up to 120 apartments and can exceed that number if specially designed. If you will be installing a larger system please contact Alpha Communications® for assistance. How many apartments will need more than 1 monitor? An apartment can have up to 4 monitors and or audio stations that will ring when the entry button is pressed.
  • Page 5 The recommended maximum number of monitors on a riser is 8-10 with each riser originating from the VSP333-3 Control Unit, including from the EVB333 Amplified Splitter(s) if your system requires them. For technical assistance and help determining equipment needed please call: Alpha Communications® at (800) 666-4800 Monday – Friday 8:30- 5:00 pm...
  • Page 6 System Notes – 2 wire COLOR with Single Modular Entry If you require more than 3 VSP333-3 Units, please use MXV333 instead. Contact Alpha Communications® for more information. A Single Entry Modular system requires the following dipswitch settings on the back of the TSMB3 unit: Switches 4, 5, &...
  • Page 7: Multiple Entry Str Modular Panels

    System Notes – 2 wire COLOR with Multiple Modular Entries If you require more than 3 VSP333-3 Units, please use MXV333 instead. Contact Alpha Communications® for more information. Multiple Entry Modular systems require the following dipswitch settings on the back of the TSMB3 unit: Switches 4,5, &6 identify the entrance number.
  • Page 8: Single Entry Custom Panel

    System Notes – 2 wire COLOR with Single Custom Panel Entry If you require more than 3 VSP333-3 Units, please use MXV333 instead. Contact Alpha Communications® for more information. The TT33-2 SPEAKER/MICROPHONE/ CONTROLLER allows you to use QwikBus™ with a custom panel or existing dry contact type entry panel by converting the button presses to a digital signal through an electronic matrix.
  • Page 9: Multiple Entry Custom Panels

    System Notes – 2 wire COLOR with Multiple Custom Panel Entries If you require more than 3 VSP333-3 Units, please use MXV333 instead. Contact Alpha Communications® for more information. Multiple Custom Panel Entry systems require the following dipswitch settings on the back of the TT33-2 units: Switch 3 If the door strike is connected to the SP333 (Tö2) = OFF (as shown at Entrance 2) Switches 4,5, &6 identify the entrance number.
  • Page 10: Important Notes On Monitor Riser Connections

    System Notes – 2 wire COLOR: Important Information on Monitor Riser Connections This section discusses the proper procedure for connecting monitors on a riser. Although a digital system is very forgiving, it is best to follow these rules during installation to maximize performance and minimize potential problems.
  • Page 11: Evb33 Distribution Units

    All Monitor BUS lines must be terminated with an End of Line resistor on the last monitor in the run. This is built into each monitor and can be installed by putting a jumper connector on J1. The location of this jumper is illustrated on Page 12. If a BUS is not terminated properly, the electronic characteristics of the line will change resulting in signal degradation and poor video quality.
  • Page 12: Dipswitch Settings

    Dipswitch Settings – Entries & Door Strikes The QwikBus™ system uses dipswitches for identification of Entry stations, additional cameras, and to enter “Programming Mode”. Entrance Panels must have a unique code so the system knows where the call is coming from and which door to open.
  • Page 13: System Camera Options - Lobby Panels, And Observation

    Entrance Panel Cameras When using a Modular system, The Modular Camera (KMBC3*) is automatically identified by being connected directly to the TT33-2 and takes the same Entrance number (1-8) of the TT33-2. When using a Custom Panel with a TT33-2 Speaker/Microphone/Controller, You can use either a pinhole or CCTV type analog camera with it’s own power supply for system video input.
  • Page 14: End Of Line Resistors Jumper Locations

    BUS End-of-Line Resistors – Jumper Locations For proper system operation, the last video monitor on a BUS riser as well as the last camera on a run must have an End-of-Line Resistors. These resistors are built in to the printed circuit boards and can be connected by installing the jumper on the two pins labeled Usually these jumpers are supplied on all the...
  • Page 15: E32 Matrix Extenders

    1 – 23 or 24 24 – 55 or 56 1 - E32 56 – 87 or 88 2 - E32 88 – 119 or 120 3 - E32 For systems larger than 120 apartments, contact Alpha Communications® for assistance.
  • Page 16: The Ic2 Database Chip

    The IC2 Database Chip The QwikBus™ system has 8 pin nonvolatile IC chips located on the back of each TSMB3 Speaker Microphone Module (in the Modular style Entry Panels) or TT33-2 Speaker Microphone Module (in the Custom style Entry Panels). Each unit has this chip which maintains the programming for that specific entry.
  • Page 17: Programming The Qwikbus™ System -- Open Voice (Vfs1500/1000)

    PROGRAMMING SECTION for OPEN VOICE STYLE NOTE: Depending on your choice of Entry Panel, you will either be using a TT33-2 or TSMB3 Module. The TT33-2 and the TSMB3 will both be referred to in this section as the Speaker/Microphone Programming the QwikBus™...
  • Page 18: One Man Bench Programming

    One Man Bench Programming -- Open Voice (VFS1500/1000 FS1500/1000) If you prefer, the system can be preprogrammed on the bench to minimize your on-site time and eliminate the necessity of a second installer. To do this the inside stations can be connected separately one after another to the Speaker/ Microphone Module (either the TSMB3 or the TT33-2) using the special programming cable (Part # EMPK-VFS/FS for handset-free type stations or Part # EMPK-VH/HT for handset type stations), or just using...
  • Page 19: Programming Vfs1500 Stations For Intercommunication

    Programming Open Voice VFS1500 for Intercommunication You can install up to five VFS1500 stations and program them for intercommunication in the same residence/ apartment. To program a VFS1500 to ring when one of the numeric buttons on another unit is pressed: 1.
  • Page 20: Programming The Qwikbus™ System --Handset (Vhc3033-2)

    PROGRAMMING SECTION for HANDSET STYLE NOTE: Depending on your choice of Entry Panel, you will either be using a TT33-2 or TSMB3 Module. The TT33-2 and the TSMB3 will both be referred to in this section as the Speaker/Microphone Programming the QwikBus™ System – Handset Style (VHC3033-2 / HT3033) Programming the system is easily done with two installers.
  • Page 21: One Man Bench Programming

    One Man Bench Programming -- Handset Style (VHC3033-2 / HT3033) If you prefer, the system can be preprogrammed on the bench to minimize your on-site time and eliminate the necessity of a second installer. To do this the inside stations can be connected separately one after another to the Speaker/ Microphone Module (either the TSMB3 or the TT33-2) using the special programming cable (Part # EMPK-VFS/FS for handset-free type stations or Part # EMPK-VH/HT for handset type stations) or by running...
  • Page 22: Vhc3033-2 Color Handset

    USER Operation of the VHC3033-2 Color Handset General Operation After a visitor has rung the bell at the entrance, the monitor will turn on automatically. You can lift the handle and talk with the visitor. You are also able to activate the door opener. When hanging up the handset, the communication will end and the monitor will turn off automatically.
  • Page 23: Vfs1500/ Vfs1000 Monitors & Fs1500/Fs1000 Audio Stations

    USER Operation of the VFS1000 / VFS1500 Open Voice COLOR Monitor & FS1000/FS1500 Audio only stations General Operation After a visitor has rung the bell at the entrance, the monitor will turn on automatically. You can push the ON/OFF button and talk with the visitor. You are also able to activate the door opener.

This manual is also suitable for:

Str qwikbus vsp333-3Str qwikbus kbs3-2

Table of Contents