Alpha Communications Art4LITE/G2 Installation Manual

Hide thumbs Also See for Art4LITE/G2:

Advertisement

Quick Links

TECHNOLOGY
Art 4 LITE/G2+ monitor
Hands-free
2-wire installation
AWD289
Rev. Feb 2021

Advertisement

Table of Contents
loading

Summary of Contents for Alpha Communications Art4LITE/G2

  • Page 1 TECHNOLOGY Art 4 LITE/G2+ monitor Hands-free 2-wire installation AWD289 Rev. Feb 2021...
  • Page 2: Table Of Contents

    ART4LITE/G2 MONITOR CONTENTS Contents ..................................2 VERY IMPORTANT (VILLA KIT: S5110 ART 4 LITE) ....................2 Set-up warnings .................................2 Characteristics................................3 System operation ...............................3 Communication with hearing aid ( ART 4H LITE/G2+ monitor only) ................3 Art 4 LITE/G2 monitor ............................4 to 20 Description ..............................4 Installation ...............................5...
  • Page 3: Characteristics

    ART4LITE/G2 MONITOR CHARACTERISTICS Hands-free monitor. - 4.3" TFT color screen - Monitor with simple installation (non-polarized 2 wires bus). - Push button for access and selection of menu function. - User menu. - Installer menu. - Image and communication settings menu.
  • Page 4: Description

    ART4LITE/G2 MONITOR DESCRIPTION MADE IN CHINA codes DIP 1 to 7 Monitor address DIP 8 resistor OFF = 0 ON = 1 D. 4.3" TFT colour screen. A. Speaker. E. Golmar use. B. Function buttons, access and selection of menu F.
  • Page 5 (with system and monitors in standby). CONFIGURATION SWITCHES (H) ART4LITE/G2 monitor with V.01 (addresses 1 to 32): Switches 1 to 5: Sets the monitor address (addresses 1 to 32). The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The monitor code is the sum of the values of the switches set to ON.
  • Page 6: Main Menu

    ART4LITE/G2 MONITOR MAIN MENU Main menu If the device is in standby (screen switched off), to access the main menu, press any of the buttons of the monitor. Then press the button located just below the corresponding icon. The device will return to standby mode after 0 seconds without activity.
  • Page 7: Settings Menu

    ART4LITE/G2 MONITOR SETTINGS MENU Settings menu Returning to the main menu: Press the button below icon to return to the main menu. Press the button below icon to " staircase light " activation (SAR-G2 + & SAR-12/24 modules required). Settings "automatic door opening" mode: See pages 8 to 10.
  • Page 8 ART4LITE/G2 MONITOR Continued from previous page. SETTINGS MENU Selecting the melody and call volume: Press the button below icon to access the settings screen. In order to identify the origin of the calls when you are not in front of the monitor, select different melodies and the desired call volume.
  • Page 9 ART4LITE/G2 MONITOR Continued from previous page. SETTINGS MENU To enable the automatic door opening (after 3 seconds of receiving a call from the door panel), go to the option with icon by pressing the button below corresponding icon and select the...
  • Page 10 ART4LITE/G2 MONITOR Continued from previous page. SETTINGS MENU Press the button below icon to return to the main menu If the ' automatic door opening ' mode is enable (see pages 8 to 9) in the top left of the screen...
  • Page 11: Door Panel Call Screen

    ART4LITE/G2 MONITOR DOOR PANEL CALL SCREEN This screen is displayed when receiving a call or pressing the button below icon of the main menu. During a call, icon displayed on the screen will blink green (during the call process). In the top...
  • Page 12: Communication Screen

    ART4LITE/G2 MONITOR COMMUNICATION SCREEN This screen is displayed during a communication process. In the top right of the screen, the source of the image is displayed. Press the button below icon to " staircase light activation (SAR-G2 " + &...
  • Page 13: Image And Communication Settings

    ART4LITE/G2 MONITOR IMAGE AND COMMUNICATION SETTINGS (Screen A) (Screen B) During a call process or during a communication process , press the button below icon for 3 seconds to access the image and monitor in call/ communication volume settings menu.
  • Page 14 ART4LITE/G2 MONITOR Continued from previous page. IMAGE AND COMMUNICATION SETTINGS The following contrast control menu will then be displayed. Adjust to the desired level by pressing the buttons below icons . To access the colour control, press the button below icon .
  • Page 15 ART4LITE/G2 MONITOR Continued from previous page. IMAGE AND COMMUNICATION SETTINGS (Screen A) The following call tone settings volume during a call process or communication settings volume during (Screen B) a communication process will then be displayed. Adjust to the desired level by pressing the buttons below icons .
  • Page 16: P Eriod Of Time For 'Do Not Disturb' Mod E Menu

    ART4LITE/G2 MONITOR PERIOD OF TIME FOR 'DO NOT DISTURB' MODE MENÚ 'Do not disturb' mode settings: If the device is in standby (screen switched off), to access the main menu, press any of the buttons of the monitor. Then press the button below icon to access the settings screen.
  • Page 17 ART4LITE/G2 MONITOR Continued from previous page. PERIOD OF TIME FOR 'DO NOT DISTURB' MODE MENÚ Time period setting screen Option selection screen Press the button below icon to return to the main menu. If the 'Do not disturb' mode is enable (see...
  • Page 18: Intercom Menu

    ART4LITE/G2 MONITOR INTERCOM MENU Access the intercom menu as described on p. . From this menu, you can contact another monitor(s) in your apartment (internal intercom) or other apartments (external intercom). For external intercom, the monitor(s) of the apartment that makes the call and the monitor(s) of the apartment that receives the call must have the intercom function...
  • Page 19 ART4LITE/G2 MONITOR Continued from previous page. INTERCOM MENU For external intercom, the monitor(s) of the apartment that makes the call and the monitor(s) of the apartment that receives the call must have the intercom function enabled: To enable/disable the intercom function between apartments, go to the option with icon...
  • Page 20 ART4LITE/G2 MONITOR Continued from previous page. INTERCOM MENU Press the button below icon to select the apartment code field to be modified, then press the buttons below icons to modify with the apartment code to be called and press the button below icon make the call.
  • Page 21: Special Codes

    ART4LITE/G2 MONITOR SPECIAL CODES The enabling of some functions, as well as the modification of some factory parameters, can be carried out by entering special codes. To do so, the installer menu must be accessed from the monitor. Go to the 'About' screen in the Settings menu (p.
  • Page 22 Important: Only available with EL632/G2SE video module with 'V03' or later. General door panels installations, available with EL632/G2SE with ’V04' or later. To define whether the monitor is master or slave (Note: ART4LITE/G2 monitor with V.02 or later): Master lave...
  • Page 23 ART4LITE/G2 MONITOR Continued from previous page. SPECIAL CODES Configuration of the remote activation button Relay1 (Door panel ). (Configure only on the master monitor). Factory setting Delay 1403 (2s) From 1400 (0.5s) to 1419 (10s) Configuration of the remote activation button Relay2 (Door panel ).
  • Page 24 1141 1140 1140 General camera 2 1181 1180 1180 General camera 3 1171 1170 1170 General camera 4 1191 1190 1190 Important: Only available with EL632/G2SE video module with 'V04' or later. Only available with monitor ART4LITE/G2 V03 or later.
  • Page 25: Cleaning The Monitor

    ART4LITE/G2 MONITOR CLEANING THE MONITOR - Do not use solvents, detergents or cleaning products that contain acids, vinegar or abrasive components. - Use a soft damp lint-free cloth with water. - Always wipe the monitor in the same direction, from top to bottom.
  • Page 26: Compliance

    ART4LITE/G2 MONITOR COMPLIANCE: This product meets the essentials requirements of applicable European Directives regarding Electromagnetic Compatibility 2014/30/ECC. NOTE: Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any received interference, including the ones that may cause undesired operation.

Table of Contents